TN Datasheet Flatpack2 Cabinatized Range v1

Flatpack2 | Cabinetized System Range 1.8 kW – 72 kW One size fits all The Flatpack 2 is the ultimate building block in any telecom application. Its power density and cost efficiency makes it ideal for loads from 1 kilowatt to several 10’s of kilowatts. With horizontal airflow, there is no limit to how many shelves of rectifiers can be stacked on top of each other, and other equipment can be mounted directly on top. Fully flexible, extremely compact: a single rectifier module that covers all your DC power requirements. Flatpack2 Power System 7.2 kW 150A www.eltekenergy.com Flatpack2 Power System 35 kW, 750A Flatpack2 Power System 72 kW, 1500A Flatpack2 | Cabinetized Range 1.8 – 72 kW Technical Specifications AC Input Voltage Frequency Maximum Current Protection Monitoring Monitoring unit Local operation Remote operation Alarm relays Visual indications Digital inputs Current measurements Alarms DC Output Voltage Current 1 phase 230 VAC 3 phase 230 VAC ( ∆ ) 3 phase 400 VAC+N ( Y ) 45 to 66Hz See Flatpack2 48VDC datasheet (241115.001.DS3) Soft start Surge protection (varistors) Internal fuses (L & N) Disconnect above 290 VAC See Smartpack (242100.100.DS3) datasheet Menu driven software via keypads and LCD or PC (PowerSuite) 32 x Breakers (2-63A) Programmable LVD 1 LVBD (150, 300, 500 or 600A) 1 LVLD (150, 300, 500 or 600A) No. of Battery fuses Connections 6 (max. 100A each) 3 (max. 200A each) 2 (max. 250A each) Battery connections Battery cable, M8 bolts Alarm connections Plug-in wire connectors front or rear access Load MCB connections Negative distribution directly from CBs. Common positive bus bars Other Specifications 3.0 KVAC – input and output 1.5 KVAC – input earth 0.5 KVDC – output earth Isolation Green LED – System ON Yellow LED – Minor alarm(s) Red LED – Major alarm(s) LCD – system status Storage temp. -40 to +85°C (-40 to +185°F) Weight /1.8m Appr. 90kg (199lbs) excl. rectifiers Weight /2.0m Appr. 97kg (214lbs) excl. rectifiers Weight /2.2m Appr. 102kg (225lbs) excl. rectifiers 6 relays are standard 6 (for monitoring of external equipment) Battery current Rectifier current Load fuse alarm Battery fuse alarm LVD operated Low output voltage alarms (2 individual alarm levels) High output voltage alarms (2 individual alarm levels) Battery capacity Temperature alarm Symmetry alarm 48 VDC From 1U PR (150A) up to 10U PR (1500A) ORDERING INFORMATION 241115.001 Load breakers PowerSuite via modem or Web NMS via SNMP-agent Specifications are subject to change without notice. Part no. DC Distribution Options Description Flatpack2 48V rectifier module Distributor in Hungary: T-Network Kft. 1142. Budapest, Ungvár u. 64-66. T: 06-1 460 9000 F: 06-1 460 9001 Email: [email protected] Operating temp. Dimensions (Ref. ETSI std) -40 to +60°C (-40 to +140°F) 600 x 600 x 1500/ 1800/ 2000/ 2200mm (wxdxh) (23.6 x 23.6 x 59/ 70.9/ 78.74/ 86.6”) Applicable Standards Electrical safety IEC 60950, UL 60950 Environment ETSI EN 300 019-2 ETSI EN 300 132-2 EMC ETSI EN 300 386 V.1.3.1 (telecommunication network) EN 61000-6-3 (emission, light industry) EN 61000-6-2 (immunity, industry)