Papers by Roswati Nurhasanah
Air preheater used in the Labuan 2 Banten PLTU is a type of tri section air preheate.From the abo... more Air preheater used in the Labuan 2 Banten PLTU is a type of tri section air preheate.From the above data so that the effect of cold element change was needed. e nd to the x-ratio value. From the results of the analysis before the element change on the cold end side can get the x-ratio value of 0.626 after the element change on the cold end side becomes 0.643 and before washing with the sootblower the x ratio value is 0.638 after washing using value sootblower x-ratio is 0.641, while in terms of effectiveness value an increase occurs before the element changes on the cold end side can be effective value of 0.656 after the element change on the cold end of the effectiveness value becomes 0.724 and before washing with sootblower the effectiveness value is 0.714 after washing using sootblower effectiveness value of 0.721
The condenser is a heat exchanger that receives heat from a Low Pressure Turbine or LP turbine wh... more The condenser is a heat exchanger that receives heat from a Low Pressure Turbine or LP turbine which is then converted into water through a condensation process. Changing process is carried out by flowing steam into a room containing pipes. Hot steam will flow outside the pipes while water as coolant flows inside the pipes. The condenser is very influential for the unit performance, so the author will discuss the condenser effectiveness in the condensing zone by comparing some operating data from condenser side A and condenser side B of PLTU Jawa Tengah 2 Adipala. The data that was used to determine the condenser effectiveness are the operating data for condenser side A and condenser side B on December 13, 2019 (before overhaul) and March 3, 2020 (after overhaul) at optimal load. Based on data processing, the effectiveness value of condenser side A on December 13, 2019 (before overhaul) has a value of 0,265 while the effectiveness of condenser side B is 0,256. After the overhaul was carried out on March 3, 2020, the effectiveness condenser side A became 0,422 while the effectiveness condenser side B became 0,4061. Comparison of the effectiveness value condenser side A before overhaul and after overhaul increased by 0,157 (37.20%). While the effectiveness value condenser side B before overhaul and after overhaul increased by 0,1501 (36,96%).
Nucleation and Atmospheric Aerosols, 2017
The effects of liquid-suction heat exchanger on the performance of a split air conditioner using ... more The effects of liquid-suction heat exchanger on the performance of a split air conditioner using R22 under various evaporating temperature
Jurnal Powerplant, 2016
The boiler is functioning equipment turn the water into steam by heating. Existing plants are spe... more The boiler is functioning equipment turn the water into steam by heating. Existing plants are specified in the supply of electrical energy required by konsumen.Effisiensi is one of the many parameters used to assess whether or not the performance of a boiler.Metode used in the calculation of boiler efficiency is the input-output method and heat losses by the aim of knowing the cause of the decrease in efficiency. Suralaya boiler efficiency analysis unit 5 meliputianalisaawaloperasidananalisasetelah terakhir.Dari overhaul both the analysis of these calculations will be elaborated based on the method of heat losses, thus resulting to a conclusion after comparison. Based on the analysis, the efficiency of the boiler when the last overhaul lower than initial efficiency of development. From the calculation of the authors analyzed the causes of decline in the efficiency and the conclusion of the decline 0.71% boiler efficiency and operation early last overhaul.
The effect of the condenser vacuum pressure on the effectiveness at Suralaya Power Plant needs to... more The effect of the condenser vacuum pressure on the effectiveness at Suralaya Power Plant needs to be maintained because a component is very influential on the effectiveness value that will be produced. The more reliable a component, the greater the value of its effectiveness. If the condenser effectiveness decreases, the resulting condenser performance will also decrease. One way to increase the efficiency of the condenser is by maintaining its properness and as a heat exchanger as a medium for using seawater as a cooling medium. The method that can be used in this research is the analysis of the effect of vacuum on the effectiveness of the condenser. This analysis is used to find effectiveness. One of the components of heat exchanger reliability is the condenser. With the analysis of its effectiveness and the calculation of the rate of cooling water temperature, it can be seen the value of its efficiency. The calculation results prove that the components in the condenser can be used as a reference for maintaining the heat exchanger components in the generator so that their effectiveness does not decrease
Journal of Advanced Research in Fluid Mechanics and Thermal Sciences, Feb 10, 2021
Low temperature storage with a single refrigeration system only stable up to 228 K temperature. T... more Low temperature storage with a single refrigeration system only stable up to 228 K temperature. The purpose of this study is to develop a low temperature cool storage with cascade refrigeration system, with hydrocarbon refrigerants in terms of energy and exergy analysis. Experimental research in laboratories using refrigerant hydrocarbon MC22 and MC134 on the hight temperature circuit, and R404A and R502 using on low temperature circuit. Condenser heat exchanger using a type of exchanger plate. Resulting from this research, obtained that result the MC22/R404A, MC22/R502 and MC134/R404A refrigerant pair can reach a temperature of 220 K. The MC22/R404A refrigerant pair has god performance, COP, total loss exergy, and exergy efficiency is better than MC22/R502, and MC134/R04A refrigerant pairs.
Arab Journal of Basic and Applied Sciences
Wind energy can be utilized by the potential of electricity by using a wind turbine, so that the ... more Wind energy can be utilized by the potential of electricity by using a wind turbine, so that the electricity raised power is greater than can be combined with the type of solar energy source. So that it can back up each other if the weather is uncertain. HOPE (Hybrid One Pole Energy) is a Hybrid power plant that is designed to exploit the potential of wind and solar energy in the campus area of PLN Jakarta Institute of Technology, from the measurement results obtained that the average wind speed is 3.5 m/s. Wind turbine designed type of wind turbine Horizontal axis, airfoil NACA 4412 type tapperless with the number of Blades 3. Data processing and simulation are done using Qblade v. 0963 software with a maximum wind speed of 12 m/s. The Material used to make this turbine blade is of teak wood. The results of the turbines of a turbine tapperless with 10 segmen, R=0,9 m α = 6o, Cl = 1.63, Cl/Cd = 133,6 and Cr = 0.18 m and Cp = 42%. From the test results acquired average power that can...
Jurnal Powerplant, 2016
The boiler is functioning equipment turn the water into steam by heating. Existing plants are spe... more The boiler is functioning equipment turn the water into steam by heating. Existing plants are specified in the supply of electrical energy required by konsumen.Effisiensi is one of the many parameters used to assess whether or not the performance of a boiler.Metode used in the calculation of boiler efficiency is the input-output method and heat losses by the aim of knowing the cause of the decrease in efficiency. Suralaya boiler efficiency analysis unit 5 meliputianalisaawaloperasidananalisasetelah terakhir.Dari overhaul both the analysis of these calculations will be elaborated based on the method of heat losses, thus resulting to a conclusion after comparison. Based on the analysis, the efficiency of the boiler when the last overhaul lower than initial efficiency of development. From the calculation of the authors analyzed the causes of decline in the efficiency and the conclusion of the decline 0.71% boiler efficiency and operation early last overhaul.
Jurnal Powerplant, 2013
This study describes the analytical calculation of cold storage for preservation planning of beef... more This study describes the analytical calculation of cold storage for preservation planning of beef in PT. Kepurun Pawana Indonesia (PT. KPI). Planning this cold storage will be addressed to the PT. KPI in Yogyakarta that one of his business is cattle farm. Because cattle results from this farm will be sold in the form of fresh beef. Therefore, these companies require cold storage for the storage of beef. Cold storage is intended to keep the quality of beef stays fresh, quality is maintained and not easily damaged or rotten. Cold storage planning begins by calculating the heat load of the product itself, followed by the calculation of the human load, load infiltration, load lighting and lighting loads. After that we can survey the price of machines such as evaporators, condensers, compressors and other equipment from the calculation that writers get. By designing the cold storage, is expected to help and solve the problem of PT. KPI itself in preserving beef before sale to consumers. Meat sales volume instability problems caused by market conditions can be overcome.
Jurnal Powerplant, 2015
Long or short time in PLTGU GRATI HSRG operate depending on the conditions of pressure HP Drum. T... more Long or short time in PLTGU GRATI HSRG operate depending on the conditions of pressure HP Drum. These pressures affect the waiting time ranges for each stage of the opening of the exhaust damper. If during the stand-by pressure HP Drum quickly run up to the pressure of <5 kg / cm2 then to operate it back it took a long time because the status has changed into a Cold. In order for the operation of the HRSG does not require a long time start-up should be done when the pressure is> 15 kg / cm2 more precisely the conditions Hot. Based on the observation chart ONLINE TEMP known cause of the pressure drop HP Drum very drastic happens during the process of the HRSG is shut down simultaneously with the circulation of HP BCP for 30 minutes after closing Exhaust Damper. From the calculation of the amount of energy lost (q loss) amounted to 1122.6 kW disistem and almost proportional to the amount of energy out of the system through the HP economizer amounted to 1328.2 kW net of energy absorption (q save) from HP Evaporator.