I got OVERSPEC, PS1 and PS2 fault led on my x3650. I tried to replace one PS but nothing changes. The power supplyp seems to work properly and it is very strange to broke both PS at the same time. I tried to reset the system log, reboot, but these leds are still on. What can i do?
-
Have you contacted IBM support? Reset the light path diags? Reset the IMM?– TheCleanerCommented Nov 18, 2013 at 13:55
-
IBM told me to contact my local IBM partner, my local partner told me to reset the bios and system log...– TobiaCommented Nov 18, 2013 at 14:27
-
see if this helps: content.etilize.com/user-manual/1023236389.pdf - normally on the xSeries a reset of the LPD itself, followed by a full shutdown (remove power cords after for 1 minute), is enough. Sometimes though, I've had to reset the IMM.– TheCleanerCommented Nov 18, 2013 at 14:59
Add a comment
|
1 Answer
Need update - Baseboard Management Controller (BMC) Version 1.44 build ID GFBT60AUS
System machine types 7978 and 1913. Please read - https://delivery04.dhe.ibm.com/sar/CMA/XSA/010ds/0/ibm_fw_bmc_gfbt60a_dos_noarch.txt
Baseboard Management Controller Version 1.44 (Build ID GFBT60AUS) - Suggested Fixes:
- Fixed the erroneous Power Supply(PS) 2 fault and recovery messages
- Fixed the problem that sometimes PS LED still on after power re-applied