To evaluate the surgical performance of the new Greenlight XPS-180W laser system (American Medica... more To evaluate the surgical performance of the new Greenlight XPS-180W laser system (American Medical Systems, Minnetonka, MI) and the effect of prostate volume (PV), in comparison with the former HPS-120W system, for the treatment of benign prostatic hyperplasia by photoselective vaporization of the prostate.
ABSTRACT To evaluate a hybrid technique involving GreenLight 120W HPS vapor incision tissue remov... more ABSTRACT To evaluate a hybrid technique involving GreenLight 120W HPS vapor incision tissue removal in prostate glands > 80 cc. Vapor incision technique (VIT) was performed in 25 consecutive men with a prostate > 80 cc by a single surgeon from May 2010 until September 2010. VIT involved adenoma incisions at 5 and 7-o'clock positions followed by 3, 9 and 12 o'clock down to the surgical capsule. Side-fire vaporization along the capsule excised transurethral resection of the prostate (TURP) like tissue strips for later retrieval. Functional evaluations were performed at 1 and 3 months. Outcomes and complications were compared retrospectively to baseline and a size matched- cohort of 25 men who previously underwent standard vaporization-only photoselective vaporization prostatectomy (PVP). The VIT and control subgroups were comparable. Mean laser time, operative time and energy usage were reduced in the VIT group compared to controls (35 min versus 48 min; 63 min versus 80 min; and 227 k versus 325 kJ respectively; all p < 0.05). At 3 months the VIT subgroup demonstrated improved Qmax and post void residual (PVR) (197% versus 173%, 88% versus 72%; all p < 0.05) compared to control. VIT showed a 68% reduction in mean preoperative PSA at 3 months compared to 50% for the control group (p<0.01). Hospital stay, catheterization time and complication rates were comparable. Our data demonstrates that VIT provides superior short term outcomes to standard HPS-PVP in men with prostate volumes > 80 cc. VIT appears to be more time-efficient, consumes less energy and obtains tissue for pathological evaluation. Further follow up is required to assess the durability of GreenLight HPS-VIT to PVP vaporization-only for large prostate glands.
To evaluate the surgical performance of the new Greenlight XPS-180W laser system (American Medica... more To evaluate the surgical performance of the new Greenlight XPS-180W laser system (American Medical Systems, Minnetonka, MI) and the effect of prostate volume (PV), in comparison with the former HPS-120W system, for the treatment of benign prostatic hyperplasia by photoselective vaporization of the prostate.
ABSTRACT To evaluate a hybrid technique involving GreenLight 120W HPS vapor incision tissue remov... more ABSTRACT To evaluate a hybrid technique involving GreenLight 120W HPS vapor incision tissue removal in prostate glands > 80 cc. Vapor incision technique (VIT) was performed in 25 consecutive men with a prostate > 80 cc by a single surgeon from May 2010 until September 2010. VIT involved adenoma incisions at 5 and 7-o'clock positions followed by 3, 9 and 12 o'clock down to the surgical capsule. Side-fire vaporization along the capsule excised transurethral resection of the prostate (TURP) like tissue strips for later retrieval. Functional evaluations were performed at 1 and 3 months. Outcomes and complications were compared retrospectively to baseline and a size matched- cohort of 25 men who previously underwent standard vaporization-only photoselective vaporization prostatectomy (PVP). The VIT and control subgroups were comparable. Mean laser time, operative time and energy usage were reduced in the VIT group compared to controls (35 min versus 48 min; 63 min versus 80 min; and 227 k versus 325 kJ respectively; all p < 0.05). At 3 months the VIT subgroup demonstrated improved Qmax and post void residual (PVR) (197% versus 173%, 88% versus 72%; all p < 0.05) compared to control. VIT showed a 68% reduction in mean preoperative PSA at 3 months compared to 50% for the control group (p<0.01). Hospital stay, catheterization time and complication rates were comparable. Our data demonstrates that VIT provides superior short term outcomes to standard HPS-PVP in men with prostate volumes > 80 cc. VIT appears to be more time-efficient, consumes less energy and obtains tissue for pathological evaluation. Further follow up is required to assess the durability of GreenLight HPS-VIT to PVP vaporization-only for large prostate glands.
Uploads
Papers by T. Ben-zvi