2006 IEEE International Symposium on Industrial Electronics, 2006
Abstract A new active compensation scheme to eliminate current harmonic components and compensate... more Abstract A new active compensation scheme to eliminate current harmonic components and compensate reactive power for high current non-linear loads is presented and analyzed. The new active compensation technique is based in a series active filter that employs a ...
IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society, 2007
Asymmetric multilevel converters can optimize the number of levels by using H bridges scaled in p... more Asymmetric multilevel converters can optimize the number of levels by using H bridges scaled in power of three. The shortcoming of this topology is that the H bridges are not interchangeable and then, under certain faulty conditions, the converter cannot operate. A reconfiguration system based on bidirectional electronic valves has been designed for 3-phase cascaded H-bridge inverters. Once a fault is detected in any of the IGBTs of any H-bridge, the control is capable to reconfigure the hardware keeping the higher power bridges in operation. In this way, the faulty phase can continue working at the same voltage level by adjusting its gating signals. Some simulations and experiments with a 27-level inverter, to show the operation of the system under a faulty condition, are displayed.
Abstract An industrial controller, specifically designed for two and three-level converters, was... more Abstract An industrial controller, specifically designed for two and three-level converters, was adapted to work on an asymmetrical, nine-level Active Power Filter (APF). The controller is now able to make all required tasks for the correct operation of the APF, such as current ...
This paper presents a multilevel converter with regeneration capability. The converter uses sever... more This paper presents a multilevel converter with regeneration capability. The converter uses several power cells connected in series, each working with reduced voltage and with an active front end at the line side. This paper presents the following: 1) the control method of each cell; 2) the use of phase-shifting techniques to reduce the current and voltage distortion; and 3) criteria to select the connection of the cells. The converter generates almost sinusoidal currents at the load and at the input and works with very high power factor.
This paper presents an overview of the state of the art in reactive power compensation technologi... more This paper presents an overview of the state of the art in reactive power compensation technologies. The principles of operation, design characteristics and application examples of Var compensators implemented with thyristors and self-commutated converters are presented. Static Var generators are used to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. Examples obtained from relevant applications describing the use of reactive power compensators implemented with new static Var technologies are also described.
IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 23, NO. 4, OCTOBER 2008 ... A New Mathematic Algorithm ... more IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 23, NO. 4, OCTOBER 2008 ... A New Mathematic Algorithm to Analyze Power ... José Mahomar, Luis Morán, Fellow, IEEE, Johan Guzmán, Member, IEEE, and Juan Dixon, Senior Member, IEEE ... AbstractThis paper presents a ...
2009 IEEE Industry Applications Society Annual Meeting, 2009
Abstract This paper presents a design method for passive filters used to compensate power factor... more Abstract This paper presents a design method for passive filters used to compensate power factor and current harmonics generated by high power cycloconverter drives. The paper includes the analysis of different passive filter topologies effectiveness (band-pass, high-pass and ...
2010 IEEE Industry Applications Society Annual Meeting, 2010
This paper presents a filter scheme implemented with passive high-pass filters and a shunt active... more This paper presents a filter scheme implemented with passive high-pass filters and a shunt active power filter. The filter scheme is aimed to compensate high power cycloconverter drives used in grinding mill plant. Passive filters are used to compensate power factor and characteristics current harmonic components generated by the cycloconverter, while the shunt active filter is designed to compensate only
2008 IEEE Power Electronics Specialists Conference, 2008
A novel N-level converter based on current-source power cells that is suitable for medium to high... more A novel N-level converter based on current-source power cells that is suitable for medium to high-voltage power applications is proposed. The topology is mainly the dual of the conventional topology based on voltage-source power cells. As such, it inherits all the advantages of the standard topology. But more importantly, the second current harmonic injected back by the normal operation of
... Please use this identifier to cite or link to this item: http://hdl.handle.net/10533/58010. T... more ... Please use this identifier to cite or link to this item: http://hdl.handle.net/10533/58010. Title: ACTIVE FILTERS. Authors: LUIS ALEJANDRO MORAN TAMAYO. Issue Date: 16-Aug-2011. Description: Texto Completo. Gov't Doc #: 1050067. URI: http://hdl.handle.net/10533/58010. ...
2009 IEEE Industry Applications Society Annual Meeting, 2009
AbstractThis paper presents a filter scheme composed by passive and series active power filters ... more AbstractThis paper presents a filter scheme composed by passive and series active power filters specially designed to compensate fundamental reactive power (with passive filters) and current harmonics (combination of passive and active). Low frequency current sub and ...
2009 IEEE Energy Conversion Congress and Exposition, 2009
A multi-cell Unified Power Quality Conditioner that operates with different DC link voltages is p... more A multi-cell Unified Power Quality Conditioner that operates with different DC link voltages is presented. Unlike what the literature reports, the DC link voltage levels are chosen to minimize the THO of the resulting AC voltage delivered by the topology for a given switching frequency. The benefits are fixed switching frequency, minimum passive component size, and high quality waveforms. In
IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society, 2011
... Munoz, Javier A.; Espinoza, Jose R.; Baier, Carlos R.; Moran, Luis A.; Guzman, Johan I.; Depa... more ... Munoz, Javier A.; Espinoza, Jose R.; Baier, Carlos R.; Moran, Luis A.; Guzman, Johan I.; Department of Industrial Technologies, Universidad de Talca ... Abstract |Full Text: PDF (1570KB); D. Soto, R. Pena and P. Wheeler, "Decoupled control of capacitor voltages in a PWM cascade ...
2008 IEEE Power Electronics Specialists Conference, 2008
Abstract A series active power filter to eliminate current harmonic components and compensate rea... more Abstract A series active power filter to eliminate current harmonic components and compensate reactive power is presented and analyzed. The proposed active compensation technique is based in a series active filter composed by two single-phase inverters ...
2008 IEEE Power Electronics Specialists Conference, 2008
AbstractThis paper presents the comparison of two control techniques, tested in a dynamic voltag... more AbstractThis paper presents the comparison of two control techniques, tested in a dynamic voltage restorer (DVR). Linear and nonlinear control schemes are compared in terms of system modeling, dynamic response, signal tracking, stability, and implementation. Mathematical, ...
2008 IEEE Power Electronics Specialists Conference, 2008
This paper presents a passive filter topology based in a dual connection, especially designed for... more This paper presents a passive filter topology based in a dual connection, especially designed for application in PWM converters. The proposed passive filter topology has the advantage of simultaneously attenuating high frequency leakage currents generated by common mode voltages and reducing the amplitude of the over-voltage at motor terminals due to wave reflection. The proposed passive filter takes advantage of
IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society, 2011
An active power filter implemented with single phase Neutral Point Clamped (NPC) multilevel conve... more An active power filter implemented with single phase Neutral Point Clamped (NPC) multilevel converters is presented and analyzed. The proposed active power filter is aimed to compensate medium voltage power distribution systems. To take advantage of the single-phase converter implementation, the proposed active power filter allows for series connection of more than one single-phase converter reaching higher blocking voltage capabilities.
2006 IEEE International Symposium on Industrial Electronics, 2006
Abstract A new active compensation scheme to eliminate current harmonic components and compensate... more Abstract A new active compensation scheme to eliminate current harmonic components and compensate reactive power for high current non-linear loads is presented and analyzed. The new active compensation technique is based in a series active filter that employs a ...
IECON 2007 - 33rd Annual Conference of the IEEE Industrial Electronics Society, 2007
Asymmetric multilevel converters can optimize the number of levels by using H bridges scaled in p... more Asymmetric multilevel converters can optimize the number of levels by using H bridges scaled in power of three. The shortcoming of this topology is that the H bridges are not interchangeable and then, under certain faulty conditions, the converter cannot operate. A reconfiguration system based on bidirectional electronic valves has been designed for 3-phase cascaded H-bridge inverters. Once a fault is detected in any of the IGBTs of any H-bridge, the control is capable to reconfigure the hardware keeping the higher power bridges in operation. In this way, the faulty phase can continue working at the same voltage level by adjusting its gating signals. Some simulations and experiments with a 27-level inverter, to show the operation of the system under a faulty condition, are displayed.
Abstract An industrial controller, specifically designed for two and three-level converters, was... more Abstract An industrial controller, specifically designed for two and three-level converters, was adapted to work on an asymmetrical, nine-level Active Power Filter (APF). The controller is now able to make all required tasks for the correct operation of the APF, such as current ...
This paper presents a multilevel converter with regeneration capability. The converter uses sever... more This paper presents a multilevel converter with regeneration capability. The converter uses several power cells connected in series, each working with reduced voltage and with an active front end at the line side. This paper presents the following: 1) the control method of each cell; 2) the use of phase-shifting techniques to reduce the current and voltage distortion; and 3) criteria to select the connection of the cells. The converter generates almost sinusoidal currents at the load and at the input and works with very high power factor.
This paper presents an overview of the state of the art in reactive power compensation technologi... more This paper presents an overview of the state of the art in reactive power compensation technologies. The principles of operation, design characteristics and application examples of Var compensators implemented with thyristors and self-commutated converters are presented. Static Var generators are used to improve voltage regulation, stability, and power factor in ac transmission and distribution systems. Examples obtained from relevant applications describing the use of reactive power compensators implemented with new static Var technologies are also described.
IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 23, NO. 4, OCTOBER 2008 ... A New Mathematic Algorithm ... more IEEE TRANSACTIONS ON POWER DELIVERY, VOL. 23, NO. 4, OCTOBER 2008 ... A New Mathematic Algorithm to Analyze Power ... José Mahomar, Luis Morán, Fellow, IEEE, Johan Guzmán, Member, IEEE, and Juan Dixon, Senior Member, IEEE ... AbstractThis paper presents a ...
2009 IEEE Industry Applications Society Annual Meeting, 2009
Abstract This paper presents a design method for passive filters used to compensate power factor... more Abstract This paper presents a design method for passive filters used to compensate power factor and current harmonics generated by high power cycloconverter drives. The paper includes the analysis of different passive filter topologies effectiveness (band-pass, high-pass and ...
2010 IEEE Industry Applications Society Annual Meeting, 2010
This paper presents a filter scheme implemented with passive high-pass filters and a shunt active... more This paper presents a filter scheme implemented with passive high-pass filters and a shunt active power filter. The filter scheme is aimed to compensate high power cycloconverter drives used in grinding mill plant. Passive filters are used to compensate power factor and characteristics current harmonic components generated by the cycloconverter, while the shunt active filter is designed to compensate only
2008 IEEE Power Electronics Specialists Conference, 2008
A novel N-level converter based on current-source power cells that is suitable for medium to high... more A novel N-level converter based on current-source power cells that is suitable for medium to high-voltage power applications is proposed. The topology is mainly the dual of the conventional topology based on voltage-source power cells. As such, it inherits all the advantages of the standard topology. But more importantly, the second current harmonic injected back by the normal operation of
... Please use this identifier to cite or link to this item: http://hdl.handle.net/10533/58010. T... more ... Please use this identifier to cite or link to this item: http://hdl.handle.net/10533/58010. Title: ACTIVE FILTERS. Authors: LUIS ALEJANDRO MORAN TAMAYO. Issue Date: 16-Aug-2011. Description: Texto Completo. Gov't Doc #: 1050067. URI: http://hdl.handle.net/10533/58010. ...
2009 IEEE Industry Applications Society Annual Meeting, 2009
AbstractThis paper presents a filter scheme composed by passive and series active power filters ... more AbstractThis paper presents a filter scheme composed by passive and series active power filters specially designed to compensate fundamental reactive power (with passive filters) and current harmonics (combination of passive and active). Low frequency current sub and ...
2009 IEEE Energy Conversion Congress and Exposition, 2009
A multi-cell Unified Power Quality Conditioner that operates with different DC link voltages is p... more A multi-cell Unified Power Quality Conditioner that operates with different DC link voltages is presented. Unlike what the literature reports, the DC link voltage levels are chosen to minimize the THO of the resulting AC voltage delivered by the topology for a given switching frequency. The benefits are fixed switching frequency, minimum passive component size, and high quality waveforms. In
IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society, 2011
... Munoz, Javier A.; Espinoza, Jose R.; Baier, Carlos R.; Moran, Luis A.; Guzman, Johan I.; Depa... more ... Munoz, Javier A.; Espinoza, Jose R.; Baier, Carlos R.; Moran, Luis A.; Guzman, Johan I.; Department of Industrial Technologies, Universidad de Talca ... Abstract |Full Text: PDF (1570KB); D. Soto, R. Pena and P. Wheeler, "Decoupled control of capacitor voltages in a PWM cascade ...
2008 IEEE Power Electronics Specialists Conference, 2008
Abstract A series active power filter to eliminate current harmonic components and compensate rea... more Abstract A series active power filter to eliminate current harmonic components and compensate reactive power is presented and analyzed. The proposed active compensation technique is based in a series active filter composed by two single-phase inverters ...
2008 IEEE Power Electronics Specialists Conference, 2008
AbstractThis paper presents the comparison of two control techniques, tested in a dynamic voltag... more AbstractThis paper presents the comparison of two control techniques, tested in a dynamic voltage restorer (DVR). Linear and nonlinear control schemes are compared in terms of system modeling, dynamic response, signal tracking, stability, and implementation. Mathematical, ...
2008 IEEE Power Electronics Specialists Conference, 2008
This paper presents a passive filter topology based in a dual connection, especially designed for... more This paper presents a passive filter topology based in a dual connection, especially designed for application in PWM converters. The proposed passive filter topology has the advantage of simultaneously attenuating high frequency leakage currents generated by common mode voltages and reducing the amplitude of the over-voltage at motor terminals due to wave reflection. The proposed passive filter takes advantage of
IECON 2011 - 37th Annual Conference of the IEEE Industrial Electronics Society, 2011
An active power filter implemented with single phase Neutral Point Clamped (NPC) multilevel conve... more An active power filter implemented with single phase Neutral Point Clamped (NPC) multilevel converters is presented and analyzed. The proposed active power filter is aimed to compensate medium voltage power distribution systems. To take advantage of the single-phase converter implementation, the proposed active power filter allows for series connection of more than one single-phase converter reaching higher blocking voltage capabilities.