^{12}C(n, 2n)^{11}C cross section from threshold to 26.5
MeV
M. Yuly, T. Eckert, G. Hartshaw, S. J. Padalino, D. N. Polsin, M. Russ, A. T. Simone, C. R.
Brune, T. N. Massey, C. E. Parker, R. Fitzgerald, T. C. Sangster, and S. P. Regan
Phys. Rev. C 97, 024613 — Published 20 February 2018
DOI: 10.1103/PhysRevC.97.024613
The
12
C(n, 2n)11 C cross section from threshold to 26.5 MeV
M. Yuly,∗ T. Eckert, and G. Hartshaw
Department of Physics, Houghton College, Houghton, New York 14744, USA
S. J. Padalino, D. N. Polsin, M. Russ, and A. T. Simone
Department of Physics, State University of New York,
Geneseo, New York 14454, USA
C. R. Brune, T. N. Massey, and C. E. Parker
Edwards Accelerator Laboratory,
Department of Physics and Astronomy,
Ohio University, Athens, Ohio 45701, USA
R. Fitzgerald
National Institute of Standards and Technology,
100 Bureau Drive, Stop 8462,
Gaithersburg, Maryland 20899-8462, USA
T. C. Sangster and S. P. Regan
Laboratory for Laser Energetics, University of Rochester,
Rochester, New York 14623, USA
The 12 C(n, 2n)11 C cross section was measured from just below threshold to 26.5 MeV using the
Pelletron accelerator at Ohio University. Monoenergetic neutrons, produced via the 3 H(d,n)4 He
reaction, were allowed to strike targets of polyethylene and graphite. Activation of both targets
was measured by counting positron annihilations resulting from the β + decay of 11 C. Annihilation
gamma rays were detected, both in coincidence and singly, using back-to-back NaI detectors. The
incident neutron flux was determined indirectly via 1 H(n,p) protons elastically scattered from the
polyethylene target. Previous measurements fall into upper and lower bands; the results of the
present measurement are consistent with the upper band.
PACS numbers: 25.40.-h
I.
INTRODUCTION
The 12 C(n, 2n)11 C reaction may be a useful and robust
neutron diagnostic for measuring the areal density ρR of
a deuterium-tritium (DT) implosion, which is an important parameter in determining the implosion compression
of an inertial confinement fusion (ICF) burn. Not only is
the reaction sensitive to ρR, but because the reaction is
only sensitive to neutrons above 20 MeV, it is immune to
primary neutrons (14.1 MeV) and down-scattered neutrons. To use this method, ultra-pure graphite disks
placed within the ICF reaction chamber become activated by tertiary neutrons via the 12 C(n, 2n)11 C reaction. The 511 keV gamma rays emitted by the 11 C disk
during positron annihilation are subsequently counted in
an area far away from the target chamber and used to
obtain the tertiary neutron yield. The diagnostic is well
suited for the harsh EMP environment produced during
∗
[email protected]
an ICF implosion and high gamma and x-ray background
[1, 2]. Furthermore, the 11 C half-life is sufficiently long
compared to the graphite extraction time which is on
the order of a few minutes. This allows for the counting
process to begin soon after the ICF shot prior to radioactive cooling of the graphite. It is important to note that
the tertiary yield cannot be determined without a good
knowledge of the 12 C(n, 2n)11 C reaction cross sections
in this energy range. Hence the importance of these new
cross section measurements.
A measurement of the 12 C(n, 2n)11 C reaction in this
energy range is also important for calculations of the rate
of cosmogenic 11 C production, since the uncertainty in
this cross section represents the largest source of systematic error in these calculations. In turn, the presence
of cosmogenic 11 C in deep underground mines limits the
detectability of pep and CNO solar neutrinos in several
neutrino experiments [3].
Figure 1 shows the previous measurements in the energy range between threshold (at 20.2957 ± 0.0010 MeV
[4]) and 35 MeV, as well as predicted cross sections from
Cross Section (mbarn)
2
positron annihilation were used to determine the number
of 11 C nuclei present. In order to determine the neutron
flux, protons from neutron-proton elastic scattering were
simultaneously counted in a ∆E-E detector telescope.
The present experiment has a number of advantages:
35
30
25
20
1. The electrostatic accelerator provides an extremely
stable and nearly mono energetic deuteron beam,
which, when used with a very thin titanium tritide
target gives intrinsic neutron energy spread of less
than about 0.2 MeV in the 20 to 30 MeV neutron
range.
15
10
5
0
22
24
26
28
30
32
34
Neutron Energy (MeV)
FIG. 1. Cross sections for the 12 C(n, 2n)11 C reaction near
threshold. The empty symbols are previously published data:
Brolley et al. (blue circles) [8], Brill et al. (pink circles) [9],
Anders et al. (green circles) [6], Welch et al. (blue triangles) [7], Soewarsono et al. (pink triangles) [10], Uno et al.
(green triangles) [11], and optical model calcualtions of Dimbylow (blue diamonds) [5]. The solid red symbols are from
this experiment using the polyethylene target and both NaI
detectors in coincidence; the larger of the associated error
bars indicates the increase in overall uncertainty when the
uncertainty in incident neutron energy is included.
Dimbylow [5], which are from a nuclear optical model
calculation using fits to experimentally measured total,
elastic and inelastic cross sections. The cross sections
tend to follow two separate bands which differ by as much
as a factor of two across the neutron energy range of interest. The upper band comprises measurements from
Anders et al. [6] and Welch et al. [7] and calculations of
Dimbylow [5], while the lower band is the measurements
from Brolley et al. [8], Brill et al. [9], Soewarsono et al
[10], and Uno et al. [11].
It is difficult to see what might be causing the results
for these experiments to fall into two distinct bands. Table I summarizes the published essential features of each
previous experiment. There does not seem to be any
obvious division between the bands on the basis of technique, type of neutron source, type of target, method
of neutron flux determination or type of activation measurement.
Since it is not clear why the previous measurements
disagree, the present experiment was designed to reduce or eliminate possible sources of systematic uncertainty that may have affected previous results. In the
present experiment, monoenergetic neutrons produced
using the 3 H(d,n)4 He reaction were allowed to strike
carbon-containing targets of polyethylene and graphite.
When these neutrons induced the 12 C(n, 2n)11 C reaction, 11 C nuclei were produced, which later decayed via
β + emission with a half-life of 20.364 ± 0.014 minutes
[12]. After an activation period, the targets were removed to counting stations, where both the singles and
coincidence rates of 511 keV gamma rays resulting from
2. By using a recoil proton telescope with ∆E-E silicon detectors, the present experiment has ability to
identify and select only 1 H(n,p) elastic recoil protons of the correct energy. Since the solid angle
is well defined and the intrinsic efficiency is nearly
100% for the silicon detectors, an absolute determination of the neutron flux is possible using well
measured np elastic scattering cross sections.
3. Two targets, graphite and the polyethylene proton
production target, irradiated and counted simultaneously, allow a consistency check. Moreover, since
the polyethylene activation target is also the proton
production target for the telescope, problems that
would result from the neutron flux being measured
in a different place than the activation target are
eliminated.
4. Counting the activated targets by placing them between the circular faces of two cylindrical matched
NaI crystals gives maximum solid angle and therefore maximum absolute efficiency for counting the
relatively small number of 11 C decays, thereby
reducing counting uncertainty and the effect of
unwanted background. Requiring a coincidence
rather than using a single detector eliminates most
background 511 keV gamma ray events that do not
come from 11 C decay.
5. A careful study was made of the absolute full-peak
efficiency of the counting system. A Monte Carlo
code was developed to calculate this efficiency for
both singles and coincidence mode geometries, the
results of which were validated by comparisons to
a number of ancillary experiments. This allowed
a consistency check to be made by simultaneously
measuring the cross sections using both the coincidence and singles count rates.
II.
DESCRIPTION OF THE EXPERIMENT
The cross sections were measured for energies between
about 19.7 and 26.4 MeV using the 4.5 MV Tandem Pelletron electrostatic accelerator at Ohio University. As
shown in Fig. 2, deuterons were accelerated to energies
between 3.1 and 9.1 MeV and allowed to strike a 472.86
3
TABLE I. Previous measurements of the
12
C(n,2n) cross section in the energy range 20-30 MeV.
Year
Experiment
Accelerator
Neutron Source
Target
Neutron Flux
Activation
Measurement
1952
Brolley et al. [8]
10.5 MeV
deuterons from
cyclotron
3
H(d,n) gas cell,
neutron energy
selected by angle
Polyethylene
foils
Calculated
from 3 H(d,n)
cross section
Geiger counter
calibrated with
RaD+E
1961
Brill et al. [9]
20 MeV
deuterons from
cyclotron, Pt foil
degrader
3
H(d,n) (Zr foil)
and 2 H(d,n)
(gas)
Carbon
TOF
energy/angle
distribution
Geiger counter
calibrated with
197
Au
1981
Anders et al. [6]
7-16 MeV
deuterons from
cyclotron, Be foil
degrader
3
H(d,n) (Ti foil)
Reactor
graphite
Stilbene
crystal recoil
proton spect.
Annihilation γ-γ
coincidence using
NaI detectors
1981
Welch et al. [7]
Tandem Van de
Graaff
3
H(d,n)
Natural
carbon
No
information
available.
Ge(Li) Detector
calibrated with
22
Na
1992
1996
Soewarsono et al.
[10]
Uno et al. [11]
20-40 MeV
protons from
cyclotron
7
7
From
activation of
Li target
HPGe
detector, Li in/out
subtraction
Li(p,n) quasimonoenergetic
GBq tritium target that was perpendicular to the beam
and located at the end of the beam pipe just upstream of
an aluminum end window. Analyzing magnet image slits
restricted the spread in deuteron beam energy to about
5 keV. Deuteron beam currents were typically between
0.8 and 1.0 µA. The tritium was deposited as titanium
tritide on a 49 mm diameter 1 mm thick OFHC copper
substrate at a density of about 2000 µg/cm2 over a circular active area of 30 mm diameter. The end window
where the target was mounted was cooled by a stream of
air. The target assembly was attached to the beamline
with a bellows so that the target could be rotated in a
circular path in a plane perpendicular the beam direction. The radius of rotation was approximately 1 cm and
the period of rotation was about 0.3 s which spread the
beam heating and target sputtering over a larger area on
the target without compromising the geometry of the experiment. Before striking the target, the deuteron beam
was defocused by a pair of quadrupole magnets located
275 and 315 cm upstream, and allowed to pass through a
1.27 cm diameter collimator 45 cm upstream of the target. This was to ensure that the beam spot on the target
was relatively large, uniform, and in a known and reproducible location. These characteristics minimized local
heating of the target and were also needed for simulations described below.
A 50 cm long steel optical bench with modified positioners was used to hold the detectors and targets in fixed
positions at an angle of 0◦ with respect to the beamline.
The targets were aligned to the optical center of the beam
line using the procedure discussed below.
Neutrons leaving the tritium could strike a 1.64 mm
thick, 2.54 cm diameter high-density polyethylene tar-
Li on
graphite
E Detector
Air dE Detector
Air
Elastically
Scattered Protons
Detector
Telescope
Graphite
Target Graphite
CH2 Plastic
Target
Neutrons
Shield
Tritium Target
Deuterons
FIG. 2. The experimental setup for activating targets.
Deuterons traveling down the beam pipe were collimated,
then struck the tritium target to produce neutrons. These
neutrons activated the graphite and polyethylene targets via
the 12 C(n,2n) reaction. The polyethylene target also acted as
the converter for the recoil proton telescope. The recoiling
protons were identified and counted using a dE-E telescope.
get with its upstream face located 7.0 cm from the tritium target and a 7.62 cm diameter 0.89 cm thick disk
of high purity graphite with a 17.46 mm hole drilled in
through its center with its upstream face 14.4 cm from
the tritium target. In contact with the upstream face of
the graphite target, a pair of graphite disks stopped any
protons scattered from the polyethylene from reaching
the graphite target. The total thickness of this graphite
shield was 3.85 mm, with the other dimensions being the
same as the graphite target disk. The mass densities of
1000
(a)
800
600
400
200
dE Detector (channel)
200
400
600
800
1000
E Detector (channel)
1000
(b)
800
600
400
200
200
400
600
800
1000
E Detector (channel)
FIG. 3. (b) Histogram of dE versus E for 23.7 MeV neutrons striking the polyethylene target. The proton island is
clearly visible. The marked region-of-interest (black) indicates the elastically scattered protons. (a) Same, but with
the polyethylene target removed.
1400
1200
Energy (keV)
the polyethylene and graphite targets were measured to
be 0.957 ± 0.008 and 1.842 ± 0.012 g/cm2 respectively.
A proton telescope consisting of a 300 µm thick, 150
mm2 ion implanted silicon dE detector and a 5000 µm
thick, 200 mm2 drifted-lithium silicon E detector was
placed behind the hole in the graphite target, so that
protons coming from the polyethylene could be viewed.
The entrance of the dE detector was covered by a 0.005
mm thick aluminum foil to keep out ambient light. The
entire detector assembly was housed in an aluminum tube
with wall thickness of about 2.9 mm and diameter of 3.47
cm. Preamplifiers and spectroscopy amplifiers located
near the detectors in the experimental hall sent pulses
to a FastComTech MPA-3 multiparameter system which
digitized and recorded the pulse heights and timing. The
system also recorded the deuteron beam current.
Fig. 3 shows 2D histograms of the pulse height in the
dE detector versus the E detector. The 1 H(n,p) protons
elastically scattered from the polyethylene can be easily
identified by their energy loss in the two detectors. At
26.4 MeV the background count rate was about 3% of
the rate with the polyethylene target in place, which was
approximately 3.5 protons/sec with a beam current of
about 1 µA. Over the course of the experiment, radiation damage caused the width of the proton peak in the
E detector to gradually increase along with the leakage
current.
A special circuit provided a separate count of the number of coincidence events, and gated the individual detector pulses that were input to analog-to-digital converters
(ADCs) that were part of the FAST ComTec MPA-3 multiparameter system. The live time, which was typically
about 98%, was confirmed by comparing the number of
coincidence events recorded by the computer with the
number counted by a separate hardware circuit.
A 12.7 cm diameter, 5.08 cm thick NE-213 liquid scintillator neutron monitor was located 300 cm from the
tritium target at an angle of a 71.4◦ to beam left. In
order to identify neutron pulses from gamma ray signals
in the monitor, a pulse shape analysis was made using a
Mesytec MPD4 pulse shape discriminator module. These
signals were also recorded by the MPA-3 multiparameter
system.
Activated targets were counted at three counting stations located in a room far from the accelerator target
area to reduce background counts. After each was activated simultaneously, the graphite target disks, shields
and polyethylene targets were placed between pairs of
7.62 cm diameter by 7.62 cm thick NaI detectors. Pairs
of detectors and the graphite targets were held with their
axes aligned inside almost equal diameter acrylic tubes.
The polyethylene targets, which were much smaller in
diameter, were affixed with adhesive tape to the center
of one of the detectors, which was marked. Pulses from
all of these detectors were digitized by a FAST ComTec
MPA-4 system, which recorded the pulse heights and timing information. Coincidence events consisting of two
back-to-back 0.511 keV gamma rays from positron anni-
dE Detector (channel)
4
1000
511 keV island
800
600
400
200
0
0
200 400
600 800 1000 1200 1400
Energy (keV)
FIG. 4. A 2D histogram showing the pulse height in each NaI
detector for coincidence events. The events in the large coincidence peak were counted for 50 second intervals to produce
the 11 B growth curve.
hilation were selected (as shown in Fig. 4) and counted as
a function of time. This allowed the growth curve of 11 B
to be measured and fit in order to determine the number
of 11 C nuclei present. The gamma rays from the graphite
shields were also counted in a separate station consisting
of two high-purity germanium detectors to look for activation due to contaminants in the graphite.
5
III.
PROCEDURE
The silicon detector telescope and targets were positioned at 0◦ to the beam line using a theodolite that had
been previously aligned with the collimator in the beam
pipe and monuments in the target room.
To ensure the polyethylene target holder was centered
and the neutron distribution was axially symmetric, a
duplicate target was cut in half and the proton count
rate was measured to approximately 2% statistical uncertainty with the half target in each of four positions, top,
bottom, left and right. The target position was changed
by simply rotating it in the holder, and the ratio of protons to integrated charge on the tritium target, which
should be constant for perfect axial symmetry, was found
to vary by less than 10%. This small deviation from
a uniform neutron distribution on the polythene target
would only result in a small correction to the already
small extended target correction described below.
For each energy setting, prior to activating the targets,
a study was made of the beam defocussing and positioning of the beam along the axis of the beam pipe. This step
is important because the distribution of the beam on the
target must be input to the simulation of the experiment
described below. Experimentally, it was observed that
steering the beam off of the central axis of the collimator would change the number of protons per integrated
charge on the tritium target and the ratio of protons to
neutrons detected in the neutron monitor. In order to
place the beam on the central axis of the quadrupoles,
the steering of the beam was adjusted such that the ratio
of detected protons to neutrons was minimally sensitive
to the the quadupole current (less than a 5% change for a
quadrupole current change of 25%). The deuteron beam
was also monitored with a beam profiler upstream from
the target. These procedures ensured that the beam was
very closely aligned with the optical beam axis and centered on the target.
Following these quadrupole tests, a shield, graphite
target and a polyethylene target were placed in the target
holders to be activated for about 1.5 hours, during which
time the proton telescope pulses were recorded. Three
identical sets of targets were available to be used consecutively in order to allow enough time for any longer lived
activated contaminants to decay between uses, although
no contaminants were detected. When the deuteron
beam was stopped, after sufficient time to allow the room
radiation dose rate to fall to an acceptable level, the targets were hand-carried to the counting room and placed
in the counting stations. The time between when irradiation stopped and when target counting commenced was
typically 4-5 minutes. Each sample was then counted for
approximately 2 hours, binned into 50 second intervals.
The dead time for each time bin was recorded and used
to correct the growth curve.
The background proton count rate was measured at
each energy setting by removing the polyethylene target
and counting for approximately 30 minutes. A separate
graphite disk target and shield was used exclusively for
this purpose.
IV.
A.
ANALYSIS
Overview
The 11 C decays in the activated polyethylene and
graphite targets were counted using pairs of NaI detectors “sandwiching” each target, capable of counting the
511 keV gamma rays from positron annihilation in both
singles and coincidence modes simultaneously. This allowed the 11 B growth curves from 11 C → 11 B + e+ + ν
to be measured for both singles and coincidence events,
and fit with the exponential growth function
R(tc ) = R0 (1 − e−λtc ) + Atc + B
(1)
where R(tc ) is the sum of all the positron annihilation
events counted up to time tc , R0 is the total number of
detectable 11 C decays, λ = 20.364 ± 0.014 min [12] is
the decay constant for 11 C and Atc + B is the integral
of the constant rate of background events. The number
of counts N0 that would be obtained if counting began
immediately at the end of activation is
N0 = R0 eλttrans
(2)
where ttrans is the time between the end of activation and
the start of counting, in other words, the time required
to transfer the samples to the counting station. The total
number of 11 C nuclei formed in the target is
N0
(3)
where is either the absolute full-peak coincidence or
singles efficiency, depending on how the growth curve was
generated.
Cross sections σ for 12 C(n,2n) were extracted using the
above quantities as well as the background-subtracted
rate of elastically scattered protons detected, Np , and
the activation time, t, since
N0 1
λ
Np
1
σ=
(4)
TC 1 − e−λt Nn Np
N11 C =
where TC is the target thickness in terms of carbon nuclei (carbon nuclei/cm2 ). The quantity (Np /Nn ) is the
ratio of elastically scattered protons detected, Np , to the
number of neutrons striking the polyethylene or graphite
target, Nn . This ratio was calculated numerically for the
experiment geometry for each target using the known
3
H(d,n)4 He [13] and 1 H(n,p)n elastic scattering [14, 15]
cross sections.
B.
Growth Curves
To determine R0 , Eq. (1) was fit to the growth curves
for the polyethylene and graphite targets using the c++
6
of protons Np using
Residual
100
Nn =
0
Integrated Counts (103)
3
30
25
20
15
10
5
(a)
20
40
60
Time (min)
80
100
FIG. 5. (a) Fit of Eq. (1) to the coincidence growth curve and
(b) residuals for the graphite target activated by 26.3 MeV
neutrons. The uncertainties shown were calculated using the
integrated number√of counts (a) and the incremental number
for each time bin Ni − Ni−1 (b).
ROOT [16] TMinuit class implementation of the Minuit
package [17]. Fits were made using singles events from
each NaI detector individually and also for coincidence
events, resulting in six semi-independent measurements
of the cross section. For the polyethylene target, which
is much thinner than the graphite, at the highest incident neutron energy setting about 7000 11 C decays were
counted over the 2 hour period.
Fig. 5 shows a typical fit of Eq. (1) to a coincidence
growth curve. These growth curves were created by integrating the number of events in the 511 keV peak up
to time tc , and plotting the integral as a function of tc .
The exponential nature of the growth curve was clear for
coincidence events, but because of the large number of
background events relative to the number of 11 C decays,
the singles growth curves for the thin polyethylene targets were nearly a straight lines. Nevertheless, the value
of R0 could still be extracted from these fits and used to
determine the cross section using Eq. (4) , albeit with a
larger uncertainty.
C.
Np
(5)
(b)
−100 ×10
0
0
1
Np
Nn
Determination of (Np /Nn )
In order to figure out the cross section for the 12 C(n,
2n)11 C reaction using Eq. (4), the incident neutron flux
Nn striking each target was determined from the number
where the quantity in parenthesis, (Np /Nn ), the ratio of
the number of protons detected to neutrons striking the
target was calculated purely from the experiment geometry.
To calculate the ratio (Np /Nn ) for each target, several
simplifying assumptions were made to which corrections
were later applied. Assume that the tritium target is a
point source of monoenergetic neutrons, isotropic in the
lab frame, with flux N (neutrons/sec/sr). In that case,
the number of neutrons/sec (Nn ) striking the polyethylene (Nn = NCH2 ) and graphite (Nn = NG ) targets
would be given by NCH2 = N ΩCH2 and NG = N ΩG
where ΩCH2 and ΩG are the solid angles of the plastic
and graphite targets, respectively, if the effect of the finite thickness of the targets on solid angle is neglected.
The number of protons/sec (Np ) detected by the proton
telescope can be obtained if the polyethylene target is
then treated as a point source for the purpose of scattering protons into the proton telescope. Assuming that the
cross section for 1 H(n,p) elastic scattering, σnp (ψnp , En ),
which depends on the scattering angle, ψnp , and the incident neutron energy, En , is roughly constant over the
angles subtended by the targets, and is equal to the cross
section at 0◦ at the nominal neutron energy, yields
Np = σnp (0◦ )TH Nn Ωp
(6)
where TH is the thickness (hydrogen nuclei/area) of the
polyethylene target, and Ωp is the solid angle of the proton telescope. In this simple approximation, therefore,
the calculated ratio of the rates for protons detected by
the proton telescope to neutrons hitting the polyethylene
target is
Np
Np
=
= σnp (0◦ )TH Ωp
(7)
Nn CH2
NCH2
and for the graphite target
Np
Np
ΩCH2 Ωp
=
= σnp (0◦ )TH
.
Nn G
NG
ΩG
(8)
Clearly, the approximation that the tritium and
polyethylene targets can be treated as point sources is
incorrect, and a more correct solution must include the
fact that the neutrons leaving the tritium target can have
a range of angles and still reach the polyethylene and
graphite targets, and that the energies and cross sections
for these neutrons depends on the neutron angle. Moreover, the protons coming from the polyethylene, which
is actually an extended source, can also have a range
of angles and still strike the proton telescope, and the
cross sections and energies of the protons reaching the
telescope depends on the proton angle.
7
based on the rate of convergence to give around 1% uncertainty in the proton-to-neutron ratio. The scattering
angles for the DT fusion and 1 H(n,p) elastic scattering
reactions for each neutron and proton path were determined for each step. No neutron scattered at an angle
of greater than around 17◦ was able to hit the graphite
target. No proton scattered at an angle greater than
around 25◦ could hit the detector. Since these extreme
angles were very unlikely, most paths had cross sections
fairly close to the 0◦ approximation.
The cross section measurement was insensitive to the
Ti:T ratio and the overall tritium activity of the tritium
target, since the neutron flux was measured directly using the proton telescope. However, the neutrons striking
the graphite and polyethylene targets are slightly reduced
in energy and have a broadened energy distribution as a
result of the deuterons losing energy prior to interact0
0
0
0
ing with the tritium, and the resulting neutrons leaving
cos φdt
×Fd Tt rt drt dθt
rdrdθ.
(9)
at angles greater than 0◦ . The thickness of the tritium
2
Rn
target was also divided into 150 steps, and for each step
where Rt is the radius of the beam spot on the tritium
in thickness and angle the energy of the neutrons striktarget (0.635 cm), R is the radius of the polyethylene taring the targets was calculated. The calculated neutron
get, the incident deuteron energy is Ed , the deuteron flux
spectra were used to correct the nominal neutron ener(deuterons/area/time) is Fd , the thickness of the tritium
gies. To do this, for neutron energies above about 21.5
target (3 H nuclei per unit area) is Tt , and the surface
MeV, where the 12 C(n, 2n)11 C cross sections are large
area of the tritium target is At . The cross section for
enough to allow, a quadratic polynomial was fit to the
DT fusion at the neutron angle φdt for incident deuteron
measured 12 C(n, 2n)11 C cross sections as a function of
energy Ed is σdt (φdt , Ed ) where φdt = cos−1 (Rn · ẑ/Rn ).
uncorrected nominal neutron energy. This was used with
The number of neutrons impacting the graphite target
the calculated neutron energy spectrum to predict the
(NG ) was calculated using the same formula by integratexpected 11 C distribution in each target. Then the toing over the surface area of the graphite target rather
tal 11 C in the target and the preliminary cross section
than the polyethylene target, remembering to include the
fit were used to determine the corrected neutron energy
central hole.
– that is, if all the neutrons had this energy, they would
give the same number of 11 C nuclei as the actual neutron
The rate of protons striking the proton telescope due
1
distribution. This process resulted in a maximum downto H(n,p) elastic scattering of DT neutrons from protons
ward shift in neutron energy of less than 1.3% (0.28 MeV)
in the plastic target is given by
which occurred for 5.57 MeV deuterons. The FWHM of
Z 2π Z Rdet Z 2π Z R Z 2π Z Rt
Np =
σnp (ψnp , En (φdt , Ed )) the energy neutron energy distribution striking the targets was typically about 0.3 MeV. For deuteron energies
0
0
0
0
0
0
below 21.5 MeV, where the 12 C(n, 2n)11 C cross section
TH
cos φdt
×σdt (φdt , Ed )Fd Tt
rt drt dθt
rdrdθ
is essentially zero, the average was used to estimate the
cos φdt
Rn2
corrected neutron energy.
cos φnp
The proton energy variation with angle for protons en×
r
dr
dθ
.
(10)
det
det
det
Rp2
tering the proton telescope is wider, but still only 5 MeV
for 26 MeV protons, which allowed the protons to be
where Rdet is the radius of the proton detector,
easily identified in the E-∆E telescope.
En (φdt , Ed ) is the DT neutron energy, which depends
Fig. 7 shows how the corrected ratio (Np /Nn ), comon the deuteron energy and DT neutron angle φdt , and
puted
using Eq. (10) and Eq. (9), compares to the ap−1
ψnp is the np scattering angle, given by ψnp = cos (Rn ·
proximate
value determined using Eq. (7) and (8). The
Rp /Rn Rp ).
net
effect
of
all these corrections was always less than
The hole through the center of the graphite target was
about
7%.
slightly too small for all of the protons to pass through
unobstructed, thereby causing a collimating effect. To
correct this, if in the integral any proton path intersected
D. Absolute Full-peak Efficiencies for Singles and
the graphite disk it was excluded from the integral. This
Coincidence
changed Np by less than 0.5%.
A c++ program was written to evaluate these integrals
Because the activated targets were sandwiched benumerically using the rectangle method. Each integral
tween the NaI detectors in order to maximize the count
was divided into 150 steps, the number of steps chosen
A number of corrections were applied to this simple
calculation of the (Np /Nn ) proton to neutron ratio. The
first correction accounts for the fact that the targets were
not point sources but actually extended targets. The
1
H(n,p) elastic scattering and DT fusion cross sections
both depend on the scattering angle, as do the energies
of the scattered neutrons and protons. To account for
these effects, the surface of each target and the silicon
detector were divided into infinitesimally small area elements, each of which was then treated as a point source.
The total number of protons or neutrons hitting a target or detector was determined by integrating over the
surface area of each target, as depicted in Fig. 6.
The rate of neutrons hitting the polyethylene target is
Z 2π Z R Z 2π Z Rt
σdt (φdt , Ed )
NCH2 =
8
CH2
Tritium
Fd
(rt, θt)
(rdet, θdet)
dt
z
Detector
Rn
Tt
np
(r, θ)
Rp
np
TH
FIG. 6. Schematic diagram showing quantities used to calculate the (Np /Nn ) proton to neutron ratio for extended targets. A
neutron can travel from an infinitesimal area element at polar coordinates (rt , θt ) on the tritium target to an area element at
polar coordinates (r, θ) on the polyethylene target along vector Rn . A proton can then travel from there to the area element
at polar coordinates (rdet , θdet ) on the detector along vector Rp . The total number of neutrons or protons were determined by
integrating over the surfaces of the involved targets or detector. The z coordinate axis is along the center of the beam line.
1.10
Ratio
1.05
1.00
0.95
0.90
2.8
4.8
6.8
En (MeV)
8.8
FIG. 7. The ratio of (Np /Nn ) determined by integration using Eq. (10) and Eq. (9) to the value determined using the
simple approximate approach of Eq. (7) and Eq. (8) for the
graphite(red squares) and the polyethylene targets (blue diamonds).
rate, the efficiency was very sensitive to geometry. A
Monte Carlo simulation was created using the Geant4
toolkit [18, 19] to model both the graphite and polyethylene target geometries, including other decay modes, surrounding materials, and Compton scattering. In order to
validate this code, it was used to predict efficiencies for
other geometries which were then tested experimentally.
These experiments will be described in more detail in a
later paper.
In the first set of tests, an associated particle technique was used to allow the absolute singles and coincidence full-peak efficiencies to be determined using an
uncalibrated 22 Na positron source. In this technique the
positrons were stopped in a plastic scintillator, signaling
that a pair of 511 keV gamma rays were released. The
fraction of plastic scintillator events for which the NaI
detector also detected a 511 keV gamma ray in coincidence is the absolute efficiency. A third detector was
used to correct for summing with the 1.274 MeV gamma
rays from the 22 Na. The geometry of the plastic scintillator and 22 Na source were simulated, and compared
with predicted singles and coincidence absolute full-peak
efficiencies as a function of source-to-detector distance
and radial source position on the face of the detector.
The code predictions agreed with the measurements to
within approximately 4.7% RMS percent difference for
coincidence, and 8.6% for singles.
The second set of tests used an approximately 3.7 kBq
NIST calibrated 68 Ge source, with activity measured to
1.7%. For the initial test, the source was sandwiched
between two copper disks to stop the positrons, nearly
simulating a point source. Again the geometry was simulated and predicted singles and coincidence absolute fullpeak efficiencies were compared with measurements as a
function of source-to-detector distance and radial source
position on the face of the detector, agreeing to about
5.3% RMS percent difference for coincidence, and 6.6%
for singles.
Finally, the 68 Ge source was placed between graphite
disks of the same diameter and approximate thickness
as in the experiment, and the full-peak efficiencies were
measured as a function of radial source position. In this
experiment, which is the closest to the actual measurement geometry, the predicted efficiencies agreed with the
measurement to 6.5% RMS percent difference for coincidence, and 1.4% for singles.
The GEANT simulation code was used to study the
effect of misaligning at axes of the targets and NaI detectors. In the worst case, which was for coincidence
measurements using the graphite target, an offset of 1
mm of the target resulted a 3.1% change in the full-peak
9
TABLE II. The absolute full-peak efficiencies used in the cross
section calculation.
Target
Graphite
Polyethylene
Configuration
Coincidence
Detector 1
Detector 2
Coincidence
Detector 1
Detector 2
Efficiency
0.0494 ± 0.0027
0.0981 ± 0.0054
0.1049 ± 0.0058
0.1568 ± 0.0078
0.1655 ± 0.0091
0.1656 ± 0.0091
efficiency.
Based on these results, a systematic uncertainty of
5.5% was assigned for the predicted absolute full-peak
efficiencies for the targets used in this experiment, which
are listed in Table II.
Given the large size of the graphite target used in this
experiment, the Monte Carlo simulation code MCNP5
[20] was used to reproduce the distribution of 11 C nuclei in the graphite disk. In this simulation, monoenergetic neutrons were emitted uniformly and isotropically
from a circular region on the flat tritium target, with a
radius equal to that of the last upstream collimator on
the deuteron beam. The interactions of these neutrons
with the graphite disk were simulated using the standard
6000.60c cross section library, and resulting number of
11
C nuclei were mesh tallied as a function of position
within the graphite. The simulation showed, relatively
independently of the neutron energy, that the number
of 11 C was reduced to about 75% at the downstream
face relative to the upstream face of the graphite, and
smoothly fell by approximately 5% from the center to
the edge. Simulating this 11 C distribution in the Geant4
code slightly increased the singles absolute full-peak efficiency for the detector with more 11 C near it and reduced the other side; for coincidences the efficiency was
increased by nearly 6%.
E.
Measurement Uncertainty
The uncertainty in the cross section from Eq. (4) was
calculated using the normal propagation of uncertainty
rules to get
(
2 2
2
δN0
δ
δTC
2
2
(δσ) = σ
+
+
N0
TC
)
2
2
δNn
1
te−λt
2
+
+
−
(δλ) .(11)
Nn
λ 1 − e−λt
where the uncertainty in the activation time t is so small
it has been neglected. The range of uncertainty values
for each term in Eq. (11) is shown in Table III, and
the results are included in the uncertainties given in Table IV and Figs. 1 and 8. The estimates for statistical
uncertainty in the number of 11 C decays result from the
error matrix calculated by TMinuit in fitting Eq. (3).
The range of values in Table III result from the large
change in the number of 11 C produced in each target,
since the 12 C(n, 2n)11 C cross section rises rapidly near
threshold. The uncertainty in the number of neutrons,
determined from (Nn /Np ) Np , depends on the statistical
uncertainty in Np the number of protons detected (about
1.1%), the uncertainty in the 1 H(n,p)n elastic scattering
cross section σnp [14, 21] (about 0.7%), the uncertainty in
TH , the polyethylene 1 H number density (about 3.5%),
and the solid angle uncertainties for the polyethylene and
graphite targets, and the proton telescope (about 2.8%,
1.4%, and 2.9% respectively). The effect of misaligning
the axes of the polyethelene and graphite targets was
simulated and found to result in approximately an additional 4.1% uncertainty in the number of neutrons striking the graphite target. Since the neutrons striking the
polyethylene target determines the number of protons,
this systematic effect does not affect the polyethylene
uncertainty. The uncertainties in the 12 C and 1 H areal
number densities (TC and TH respectively) for each of the
targets was estimated based on careful measurements of
the target dimensions and mass.
The uncertainty in the corrected incident neutron energy was assumed due to the uncertainty in the thickness of the tritium target, which was about ±0.7%.
The neutron energy uncertainty was propagated into the
12
C(n, 2n)11 C cross section uncertainty using the slope
of a polynomial fit to the nominal 12 C(n, 2n)11 C cross
sections as a function of energy. The resulting cross section uncertainties, which ranged from 0.31 mb to 0.85
mb, were added in quadrature to the other uncertainties
described above.
V.
DISCUSSION OF EXPERIMENTAL
RESULTS
The total 12 C(n,2n)11 C cross sections obtained from
the graphite and polyethylene targets, for coincidence
and singles counting, are displayed in Table IV. The
agreement between cross sections determined using different targets, geometries, efficiencies and detectors is
quite good; the overall RMS percent difference from the
mean for energies above 22 MeV, where there are enough
statistics to be meaningful, is 6.2%. The best individual
measurement is expected to be the coincidence measurement using the polyethylene target, since the background
rate is reduced for the coincidence measurement, allowing
a more robust fit to the growth curve, and since the same
target is used for 1 H(n,p) elastic scattering, eliminating
systematic uncertainties in determining the neutron flux.
Fig. 8 plots the cross sections measured in this experiment for different combinations of targets and detectors. Fig. 8a shows the overall agreement between
all of the measurements made at each neutron energy.
The agreement is good, but with the graphite coincidence measurement being systematically high. Figs. 8b,
c and d compare just the polyethylene and graphite cross
10
TABLE III. Contribution to the cross section uncertainty
from each term in Eq. (11) corresponding to the factors in
Eq. (4). For the statistical uncertainties in the number of 11 C
and incident neutrons, the ranges given are for energies above
about 21.5 MeV, where the cross section is large enough for
this to be meaningful.
Percent
Uncertainty
Source
Uncertainty in N0
Graphite target
11
C decays counted
11
C decays counted
11
C decays counted
Polyethylene target
11
C decays counted
11
C decays counted
11
C decays counted
in coincidence
in NaI1 detector
in NaI2 detector
0.3-0.9%
0.2-1.0%
0.2-1.0%
in coincidence
in NaI1 detector
in NaI2 detector
0.7-2.3%
1.0-9.5%
1.0-5.5%
Uncertainty in NaI detector efficiency
5.5%
Uncertainty in 12 C areal number density TC
Graphite target
Polyethylene target
1.9%
3.8%
Uncertainty in incident neutrons Nn
Graphite target
Polyethylene target
6.9%
4.6%
Uncertainty in λ/1 − e−λt
0.6%
sections for coincidence and singles measurements using
each detector. Comparing measurements with different
targets made using the same detector(s) shows agreement
within experimental uncertainty, which is a fairly stringent test since the geometry and target material is not
the same, supporting the calculated detector efficiency
and geometry correction. The measurement at 24.7 MeV
was repeated, the first measurement made near the middle of the experiment and the second at the end. In this
case, the coincidence measurements at the middle and
end of the experiment agree when comparing graphite
to graphite and polyethylene to polyethylene, but the
graphite result is higher than the polyethylene for both
measurements, slightly outside of the error bars.
It is clear from Fig. 1 that the cross sections from the
present experiment fall along high side of the upper curve
previously set by the measurements of Anders et al. [6]
and Welch et al. [7] and calculations of Dimbylow [5].
The predictions of Dimbylow [5] are within our error bars,
as are, for the most part, the measurements from Anders
et al [6] and Welch et al. [7].
VI.
CONCLUSION
The cross sections for 12 C(n, 2n)11 C have been measured using an activation technique from threshold to
26.3 MeV with an uncertainty of approximately 9-12%
for the higher energies. Previous measurements disagree,
tending to fall into upper and lower bands. The results
of the present experiment agree with the upper band.
Accurate cross sections may allow the 12 C(n, 2n) reaction to be used as neutron diagnostic for ICF. During an
ICF implosion, primary and tertiary DT fusion reaction
neutrons are produced. Since the ion plasma temperatures in these thermonuclear implosions are typically in
the keV range, the primary DT neutron energy is Q value
driven. The energy distribution of primary neutrons is
typically peaked around 14.1 MeV and has a small thermodynamic width which is broadened further via straggling by the compressed fuel. These neutrons are copious and exceed the production of tertiary neutrons by
six to seven orders of magnitude. Conversely, neutrons
which are produced by DT fusion reactions caused by upscattered MeV DT fuel generate tertiary neutrons with
energies in the 10 to 32 MeV range. Since the 12 C(n, 2n)
reaction is insensitive to energies below 20 MeV, the primary 14.1 MeV DT and down scattered primary neutrons
cannot react with the carbon. Only tertiary neutrons in
20 to 32 MeV range react making this method useful as
a possible ICF tertiary neutron diagnostic.
To use this method, ultra-pure graphite disks placed
within the ICF reaction chamber become activated by
tertiary neutrons via the 12 C(n, 2n)11 C reaction. The
11
C in the disk subsequently decays via positron emission, and the 511 keV annihilation gamma rays are then
counted in coincidence using a detector system far from
the target chamber. The gamma counts can then be used
to obtain the tertiary neutron yield, limited by the uncertainty in the 12 C(n, 2n)11 C cross section.
ACKNOWLEDGMENTS
We would like to thank Andrew Evans, Keith Mann,
Tyler Reynolds, Ian Love, August Gula, Laurel Vincett,
Lee Gabler, Michael Krieger, Mollie Bienstock, Collin
Stillman, Drew Ellison, and Holly Desmitt for assistance
performing the experiment, and Shamim Akhtar, Don
Carter, Sushil Dhakal, Devon Jacobs, John O’Donnell,
and Andrea Richard for assistance at Ohio University.
This research is funded in part by the University of
Rochester Laboratory for Laser Energetics through a
grant from the Department of Energy and by the U.S.
Department of Energy, under Grant Nos. DE-FG0288ER40387, DE-NA0001837, and DE-NA0002905.
Certain commercial equipment, instruments, or materials are identified in this paper to foster understanding.
Such identification does not imply recommendation or
endorsement by the National Institute of Standards and
Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the
purpose.
11
TABLE IV. Total 12 C(n, 2n)11 C cross sections obtained from the graphite and polyethylene targets, for coincidence and singles
counting. Also shown is the weighted mean for each energy. The uncertainties quoted are discussed in the text.
Deuteron
Energy
(MeV)
3.57
4.07
4.57
5.07
5.57
6.07
6.57
7.07
7.57
7.57
8.07
8.57
9.07
Energy
(MeV)
20.06
20.67
21.27
21.79
22.35
22.92
23.51
24.11
24.69
24.69
25.25
25.77
26.25
Graphite
Coincidence
Detector 1
(mb)
(mb)
0.00 ± 0.00
-0.05 ± 0.01
0.08 ± 0.01
0.07 ± 0.01
0.78 ± 0.32
0.75 ± 0.31
2.69 ± 0.43
4.03 ± 0.51
4.37 ± 0.57
4.23 ± 0.56
6.76 ± 0.77
6.56 ± 0.76
8.19 ± 0.92
7.72 ± 0.88
8.89 ± 1.01
8.53 ± 0.98
12.34 ± 1.31 11.62 ± 1.26
12.19 ± 1.30
9.66 ± 1.11
13.45 ± 1.44 12.62 ± 1.37
15.91 ± 1.67 13.86 ± 1.51
18.16 ± 1.89 16.80 ± 1.78
Detector 2
(mb)
0.02 ± 0.01
0.10 ± 0.01
0.70 ± 0.31
3.78 ± 0.49
3.96 ± 0.54
6.12 ± 0.73
7.25 ± 0.85
7.83 ± 0.93
11.17 ± 1.22
9.04 ± 1.06
11.81 ± 1.31
13.05 ± 1.44
16.07 ± 1.72
[1] D. Welch, H. Kislev, and G. Miley, Rev Sci Instrum 59,
610 (1988).
[2] V. Y. Glebov, C. Stoeckl, T. Sangster, D. Meyerhofer,
P. Radha, S. Padalino, L. Baumgart, R. Colburn, and
J. Fuschino, Rev Sci Instrum 74, 1717 (2003).
[3] C. Galbiati, A. Pocar, D. Franco, A. Ianni, L. Cadonati,
and S. Schönert, Phys. Rev. C 71, 055805 (2005).
[4] G. Audi, F. Kondev, M. Wang, B. Pfeiffer, X. Sun, J. Blachot, and M. MacCormick, Chin. Phys. C 36, 1157
(2012).
[5] P. Dimbylow, Phys. Med. Biol. 25, 637 (1980).
[6] B. Anders, P. Herges, and W. Scobel, Z. Phys. A 301,
353 (1981).
[7] P. Welch, J. Johnson, G. Randers-Pehrson, and J. Rapaport, Bull. Am. Phys. Soc 26, 708 (1981).
[8] J. Brolley Jr, J. Fowler, and L. Schlacks, Phys. Rev. 88,
618 (1952).
[9] O. D. Brill, N. A. Vlasov, S. P. Kalinin, and L. S.
Sokolov, Dok. Akad. Nauk SSSR 136, 55 (1961), [Sov.
Phys. Dokl. 6, 24-26 (1961)].
[10] T. S. Soewarsono, Y. Uwamino, and T. Nakamura, in
Proceedings of the 1991 Symposium on Nuclear Data,
JAERI-M 92-027, edited by M. Baba and T. Nakagawa
(Tokyo, Tokai, Ibaraki-ken. Japan, 1992) pp. 354–363.
[11] Y. Uno, Y. Uwamino, T. S. Soewarsono, and T. Nakamura, Nucl Sci Eng 122, 247 (1996).
Energy
(MeV)
20.10
20.71
21.31
21.83
22.39
22.97
23.56
24.15
24.74
24.74
25.29
25.82
26.29
Polyethylene
Coincidence
Detector 1
(mb)
(mb)
0.00 ± 0.01
-0.03 ± 0.13
0.08 ± 0.01
0.50 ± 0.11
0.88 ± 0.32
0.79 ± 0.33
2.53 ± 0.41
4.04 ± 0.49
4.02 ± 0.52
4.14 ± 0.53
6.49 ± 0.70
6.00 ± 0.69
7.58 ± 0.80
7.43 ± 0.80
8.50 ± 0.90
8.18 ± 0.88
11.09 ± 1.10 10.70 ± 1.08
10.77 ± 1.08
8.58 ± 0.95
12.04 ± 1.20 11.44 ± 1.16
13.91 ± 1.36 13.36 ± 1.32
16.55 ± 1.56 16.43 ± 1.56
Detector 2
(mb)
-0.20 ± 0.01
0.12 ± 0.01
1.49 ± 0.32
3.72 ± 0.41
3.83 ± 0.52
6.44 ± 0.70
7.48 ± 0.80
8.49 ± 0.90
10.77 ± 1.10
9.59 ± 1.08
12.75 ± 1.20
12.57 ± 1.36
16.94 ± 1.56
[12] J. H. Kelley, E. Kwan, J. Purcell, C. Sheu, and H. Weller,
Nucl. Phys. A 880, 88 (2012).
[13] M. Drosg, DROSG-2000: Neutron source reactions.,
Tech. Rep. IAEA-NDS-87 Rev. 5 (International Atomic
Energy Agency, Nuclear Data Section, Vienna (Austria),
2000).
[14] V. Stoks, R. Klomp, M. Rentmeester, and J. De Swart,
Phys. Rev. C 48, 792 (1993).
[15] V. Stoks, R. Klomp, C. Terheggen, and J. De Swart,
Phys. Rev. C 49, 2950 (1994).
[16] R. Brun and F. Rademakers, Nucl. Instrum. Methods
Phys. Res. A 389, 81 (1997).
[17] F. James and M. Winkler, MINUIT–Users Guide, Program Library D506, CERN, Geneva (1998).
[18] S. Agostinelli, J. Allison, K. a. Amako, J. Apostolakis,
H. Araujo, P. Arce, M. Asai, D. Axen, S. Banerjee,
G. Barrand, et al., Nucl. Instrum. Methods Phys. Res.
A 506, 250 (2003).
[19] J. Allison, K. Amako, J. e. a. Apostolakis, H. Araujo,
P. A. Dubois, M. Asai, G. Barrand, R. Capra, S. Chauvie,
R. Chytracek, et al., Nuclear Science, IEEE Transactions
on 53, 270 (2006).
[20] X. Team, Los Alamos National Lab Report: LA-UR-031987 (2003).
[21] V. Stoks, R. Timmermans, and J. De Swart, Phys. Rev.
C 47, 512 (1993).
Cross Section (mbarn)
12
20
20
(a)
(b)
15
15
10
10
5
5
0
20
0
20
21
22
23
24
25
26
20
20
(c)
15
10
10
5
5
0
0
21
22
23
24
25
26
22
23
24
25
26
(d)
15
20
21
22
23
24
25
26
20
21
Neutron Energy (MeV)
FIG. 8. Comparison of the cross sections measured in this experiment using the graphite (circles) and polyethylene (diamonds)
targets for (b) both NaI detectors in coincidence (red), and (c) NaI detector 1 (blue) and (d) NaI detector 2 (green) in singles
mode. Figure (a) shows cross sections determined using both coincidence and singles information for both targets on the same
plot. For each cross section, the larger of the associated error bars indicates the increase in overall uncertainty when the
uncertainty in incident neutron energy is included.