Academia.eduAcademia.edu

C12(n, 2n)C11 cross section from threshold to 26.5 MeV

2018, Physical Review C

The 12 C(n, 2n) 11 C cross section from threshold to 26.

This is the accepted manuscript made available via CHORUS. The article has been published as: ^{12}C(n, 2n)^{11}C cross section from threshold to 26.5 MeV M. Yuly, T. Eckert, G. Hartshaw, S. J. Padalino, D. N. Polsin, M. Russ, A. T. Simone, C. R. Brune, T. N. Massey, C. E. Parker, R. Fitzgerald, T. C. Sangster, and S. P. Regan Phys. Rev. C 97, 024613 — Published 20 February 2018 DOI: 10.1103/PhysRevC.97.024613 The 12 C(n, 2n)11 C cross section from threshold to 26.5 MeV M. Yuly,∗ T. Eckert, and G. Hartshaw Department of Physics, Houghton College, Houghton, New York 14744, USA S. J. Padalino, D. N. Polsin, M. Russ, and A. T. Simone Department of Physics, State University of New York, Geneseo, New York 14454, USA C. R. Brune, T. N. Massey, and C. E. Parker Edwards Accelerator Laboratory, Department of Physics and Astronomy, Ohio University, Athens, Ohio 45701, USA R. Fitzgerald National Institute of Standards and Technology, 100 Bureau Drive, Stop 8462, Gaithersburg, Maryland 20899-8462, USA T. C. Sangster and S. P. Regan Laboratory for Laser Energetics, University of Rochester, Rochester, New York 14623, USA The 12 C(n, 2n)11 C cross section was measured from just below threshold to 26.5 MeV using the Pelletron accelerator at Ohio University. Monoenergetic neutrons, produced via the 3 H(d,n)4 He reaction, were allowed to strike targets of polyethylene and graphite. Activation of both targets was measured by counting positron annihilations resulting from the β + decay of 11 C. Annihilation gamma rays were detected, both in coincidence and singly, using back-to-back NaI detectors. The incident neutron flux was determined indirectly via 1 H(n,p) protons elastically scattered from the polyethylene target. Previous measurements fall into upper and lower bands; the results of the present measurement are consistent with the upper band. PACS numbers: 25.40.-h I. INTRODUCTION The 12 C(n, 2n)11 C reaction may be a useful and robust neutron diagnostic for measuring the areal density ρR of a deuterium-tritium (DT) implosion, which is an important parameter in determining the implosion compression of an inertial confinement fusion (ICF) burn. Not only is the reaction sensitive to ρR, but because the reaction is only sensitive to neutrons above 20 MeV, it is immune to primary neutrons (14.1 MeV) and down-scattered neutrons. To use this method, ultra-pure graphite disks placed within the ICF reaction chamber become activated by tertiary neutrons via the 12 C(n, 2n)11 C reaction. The 511 keV gamma rays emitted by the 11 C disk during positron annihilation are subsequently counted in an area far away from the target chamber and used to obtain the tertiary neutron yield. The diagnostic is well suited for the harsh EMP environment produced during ∗ [email protected] an ICF implosion and high gamma and x-ray background [1, 2]. Furthermore, the 11 C half-life is sufficiently long compared to the graphite extraction time which is on the order of a few minutes. This allows for the counting process to begin soon after the ICF shot prior to radioactive cooling of the graphite. It is important to note that the tertiary yield cannot be determined without a good knowledge of the 12 C(n, 2n)11 C reaction cross sections in this energy range. Hence the importance of these new cross section measurements. A measurement of the 12 C(n, 2n)11 C reaction in this energy range is also important for calculations of the rate of cosmogenic 11 C production, since the uncertainty in this cross section represents the largest source of systematic error in these calculations. In turn, the presence of cosmogenic 11 C in deep underground mines limits the detectability of pep and CNO solar neutrinos in several neutrino experiments [3]. Figure 1 shows the previous measurements in the energy range between threshold (at 20.2957 ± 0.0010 MeV [4]) and 35 MeV, as well as predicted cross sections from Cross Section (mbarn) 2 positron annihilation were used to determine the number of 11 C nuclei present. In order to determine the neutron flux, protons from neutron-proton elastic scattering were simultaneously counted in a ∆E-E detector telescope. The present experiment has a number of advantages: 35 30 25 20 1. The electrostatic accelerator provides an extremely stable and nearly mono energetic deuteron beam, which, when used with a very thin titanium tritide target gives intrinsic neutron energy spread of less than about 0.2 MeV in the 20 to 30 MeV neutron range. 15 10 5 0 22 24 26 28 30 32 34 Neutron Energy (MeV) FIG. 1. Cross sections for the 12 C(n, 2n)11 C reaction near threshold. The empty symbols are previously published data: Brolley et al. (blue circles) [8], Brill et al. (pink circles) [9], Anders et al. (green circles) [6], Welch et al. (blue triangles) [7], Soewarsono et al. (pink triangles) [10], Uno et al. (green triangles) [11], and optical model calcualtions of Dimbylow (blue diamonds) [5]. The solid red symbols are from this experiment using the polyethylene target and both NaI detectors in coincidence; the larger of the associated error bars indicates the increase in overall uncertainty when the uncertainty in incident neutron energy is included. Dimbylow [5], which are from a nuclear optical model calculation using fits to experimentally measured total, elastic and inelastic cross sections. The cross sections tend to follow two separate bands which differ by as much as a factor of two across the neutron energy range of interest. The upper band comprises measurements from Anders et al. [6] and Welch et al. [7] and calculations of Dimbylow [5], while the lower band is the measurements from Brolley et al. [8], Brill et al. [9], Soewarsono et al [10], and Uno et al. [11]. It is difficult to see what might be causing the results for these experiments to fall into two distinct bands. Table I summarizes the published essential features of each previous experiment. There does not seem to be any obvious division between the bands on the basis of technique, type of neutron source, type of target, method of neutron flux determination or type of activation measurement. Since it is not clear why the previous measurements disagree, the present experiment was designed to reduce or eliminate possible sources of systematic uncertainty that may have affected previous results. In the present experiment, monoenergetic neutrons produced using the 3 H(d,n)4 He reaction were allowed to strike carbon-containing targets of polyethylene and graphite. When these neutrons induced the 12 C(n, 2n)11 C reaction, 11 C nuclei were produced, which later decayed via β + emission with a half-life of 20.364 ± 0.014 minutes [12]. After an activation period, the targets were removed to counting stations, where both the singles and coincidence rates of 511 keV gamma rays resulting from 2. By using a recoil proton telescope with ∆E-E silicon detectors, the present experiment has ability to identify and select only 1 H(n,p) elastic recoil protons of the correct energy. Since the solid angle is well defined and the intrinsic efficiency is nearly 100% for the silicon detectors, an absolute determination of the neutron flux is possible using well measured np elastic scattering cross sections. 3. Two targets, graphite and the polyethylene proton production target, irradiated and counted simultaneously, allow a consistency check. Moreover, since the polyethylene activation target is also the proton production target for the telescope, problems that would result from the neutron flux being measured in a different place than the activation target are eliminated. 4. Counting the activated targets by placing them between the circular faces of two cylindrical matched NaI crystals gives maximum solid angle and therefore maximum absolute efficiency for counting the relatively small number of 11 C decays, thereby reducing counting uncertainty and the effect of unwanted background. Requiring a coincidence rather than using a single detector eliminates most background 511 keV gamma ray events that do not come from 11 C decay. 5. A careful study was made of the absolute full-peak efficiency of the counting system. A Monte Carlo code was developed to calculate this efficiency for both singles and coincidence mode geometries, the results of which were validated by comparisons to a number of ancillary experiments. This allowed a consistency check to be made by simultaneously measuring the cross sections using both the coincidence and singles count rates. II. DESCRIPTION OF THE EXPERIMENT The cross sections were measured for energies between about 19.7 and 26.4 MeV using the 4.5 MV Tandem Pelletron electrostatic accelerator at Ohio University. As shown in Fig. 2, deuterons were accelerated to energies between 3.1 and 9.1 MeV and allowed to strike a 472.86 3 TABLE I. Previous measurements of the 12 C(n,2n) cross section in the energy range 20-30 MeV. Year Experiment Accelerator Neutron Source Target Neutron Flux Activation Measurement 1952 Brolley et al. [8] 10.5 MeV deuterons from cyclotron 3 H(d,n) gas cell, neutron energy selected by angle Polyethylene foils Calculated from 3 H(d,n) cross section Geiger counter calibrated with RaD+E 1961 Brill et al. [9] 20 MeV deuterons from cyclotron, Pt foil degrader 3 H(d,n) (Zr foil) and 2 H(d,n) (gas) Carbon TOF energy/angle distribution Geiger counter calibrated with 197 Au 1981 Anders et al. [6] 7-16 MeV deuterons from cyclotron, Be foil degrader 3 H(d,n) (Ti foil) Reactor graphite Stilbene crystal recoil proton spect. Annihilation γ-γ coincidence using NaI detectors 1981 Welch et al. [7] Tandem Van de Graaff 3 H(d,n) Natural carbon No information available. Ge(Li) Detector calibrated with 22 Na 1992 1996 Soewarsono et al. [10] Uno et al. [11] 20-40 MeV protons from cyclotron 7 7 From activation of Li target HPGe detector, Li in/out subtraction Li(p,n) quasimonoenergetic GBq tritium target that was perpendicular to the beam and located at the end of the beam pipe just upstream of an aluminum end window. Analyzing magnet image slits restricted the spread in deuteron beam energy to about 5 keV. Deuteron beam currents were typically between 0.8 and 1.0 µA. The tritium was deposited as titanium tritide on a 49 mm diameter 1 mm thick OFHC copper substrate at a density of about 2000 µg/cm2 over a circular active area of 30 mm diameter. The end window where the target was mounted was cooled by a stream of air. The target assembly was attached to the beamline with a bellows so that the target could be rotated in a circular path in a plane perpendicular the beam direction. The radius of rotation was approximately 1 cm and the period of rotation was about 0.3 s which spread the beam heating and target sputtering over a larger area on the target without compromising the geometry of the experiment. Before striking the target, the deuteron beam was defocused by a pair of quadrupole magnets located 275 and 315 cm upstream, and allowed to pass through a 1.27 cm diameter collimator 45 cm upstream of the target. This was to ensure that the beam spot on the target was relatively large, uniform, and in a known and reproducible location. These characteristics minimized local heating of the target and were also needed for simulations described below. A 50 cm long steel optical bench with modified positioners was used to hold the detectors and targets in fixed positions at an angle of 0◦ with respect to the beamline. The targets were aligned to the optical center of the beam line using the procedure discussed below. Neutrons leaving the tritium could strike a 1.64 mm thick, 2.54 cm diameter high-density polyethylene tar- Li on graphite E Detector Air dE Detector Air Elastically Scattered Protons Detector Telescope Graphite Target Graphite CH2 Plastic Target Neutrons Shield Tritium Target Deuterons FIG. 2. The experimental setup for activating targets. Deuterons traveling down the beam pipe were collimated, then struck the tritium target to produce neutrons. These neutrons activated the graphite and polyethylene targets via the 12 C(n,2n) reaction. The polyethylene target also acted as the converter for the recoil proton telescope. The recoiling protons were identified and counted using a dE-E telescope. get with its upstream face located 7.0 cm from the tritium target and a 7.62 cm diameter 0.89 cm thick disk of high purity graphite with a 17.46 mm hole drilled in through its center with its upstream face 14.4 cm from the tritium target. In contact with the upstream face of the graphite target, a pair of graphite disks stopped any protons scattered from the polyethylene from reaching the graphite target. The total thickness of this graphite shield was 3.85 mm, with the other dimensions being the same as the graphite target disk. The mass densities of 1000 (a) 800 600 400 200 dE Detector (channel) 200 400 600 800 1000 E Detector (channel) 1000 (b) 800 600 400 200 200 400 600 800 1000 E Detector (channel) FIG. 3. (b) Histogram of dE versus E for 23.7 MeV neutrons striking the polyethylene target. The proton island is clearly visible. The marked region-of-interest (black) indicates the elastically scattered protons. (a) Same, but with the polyethylene target removed. 1400 1200 Energy (keV) the polyethylene and graphite targets were measured to be 0.957 ± 0.008 and 1.842 ± 0.012 g/cm2 respectively. A proton telescope consisting of a 300 µm thick, 150 mm2 ion implanted silicon dE detector and a 5000 µm thick, 200 mm2 drifted-lithium silicon E detector was placed behind the hole in the graphite target, so that protons coming from the polyethylene could be viewed. The entrance of the dE detector was covered by a 0.005 mm thick aluminum foil to keep out ambient light. The entire detector assembly was housed in an aluminum tube with wall thickness of about 2.9 mm and diameter of 3.47 cm. Preamplifiers and spectroscopy amplifiers located near the detectors in the experimental hall sent pulses to a FastComTech MPA-3 multiparameter system which digitized and recorded the pulse heights and timing. The system also recorded the deuteron beam current. Fig. 3 shows 2D histograms of the pulse height in the dE detector versus the E detector. The 1 H(n,p) protons elastically scattered from the polyethylene can be easily identified by their energy loss in the two detectors. At 26.4 MeV the background count rate was about 3% of the rate with the polyethylene target in place, which was approximately 3.5 protons/sec with a beam current of about 1 µA. Over the course of the experiment, radiation damage caused the width of the proton peak in the E detector to gradually increase along with the leakage current. A special circuit provided a separate count of the number of coincidence events, and gated the individual detector pulses that were input to analog-to-digital converters (ADCs) that were part of the FAST ComTec MPA-3 multiparameter system. The live time, which was typically about 98%, was confirmed by comparing the number of coincidence events recorded by the computer with the number counted by a separate hardware circuit. A 12.7 cm diameter, 5.08 cm thick NE-213 liquid scintillator neutron monitor was located 300 cm from the tritium target at an angle of a 71.4◦ to beam left. In order to identify neutron pulses from gamma ray signals in the monitor, a pulse shape analysis was made using a Mesytec MPD4 pulse shape discriminator module. These signals were also recorded by the MPA-3 multiparameter system. Activated targets were counted at three counting stations located in a room far from the accelerator target area to reduce background counts. After each was activated simultaneously, the graphite target disks, shields and polyethylene targets were placed between pairs of 7.62 cm diameter by 7.62 cm thick NaI detectors. Pairs of detectors and the graphite targets were held with their axes aligned inside almost equal diameter acrylic tubes. The polyethylene targets, which were much smaller in diameter, were affixed with adhesive tape to the center of one of the detectors, which was marked. Pulses from all of these detectors were digitized by a FAST ComTec MPA-4 system, which recorded the pulse heights and timing information. Coincidence events consisting of two back-to-back 0.511 keV gamma rays from positron anni- dE Detector (channel) 4 1000 511 keV island 800 600 400 200 0 0 200 400 600 800 1000 1200 1400 Energy (keV) FIG. 4. A 2D histogram showing the pulse height in each NaI detector for coincidence events. The events in the large coincidence peak were counted for 50 second intervals to produce the 11 B growth curve. hilation were selected (as shown in Fig. 4) and counted as a function of time. This allowed the growth curve of 11 B to be measured and fit in order to determine the number of 11 C nuclei present. The gamma rays from the graphite shields were also counted in a separate station consisting of two high-purity germanium detectors to look for activation due to contaminants in the graphite. 5 III. PROCEDURE The silicon detector telescope and targets were positioned at 0◦ to the beam line using a theodolite that had been previously aligned with the collimator in the beam pipe and monuments in the target room. To ensure the polyethylene target holder was centered and the neutron distribution was axially symmetric, a duplicate target was cut in half and the proton count rate was measured to approximately 2% statistical uncertainty with the half target in each of four positions, top, bottom, left and right. The target position was changed by simply rotating it in the holder, and the ratio of protons to integrated charge on the tritium target, which should be constant for perfect axial symmetry, was found to vary by less than 10%. This small deviation from a uniform neutron distribution on the polythene target would only result in a small correction to the already small extended target correction described below. For each energy setting, prior to activating the targets, a study was made of the beam defocussing and positioning of the beam along the axis of the beam pipe. This step is important because the distribution of the beam on the target must be input to the simulation of the experiment described below. Experimentally, it was observed that steering the beam off of the central axis of the collimator would change the number of protons per integrated charge on the tritium target and the ratio of protons to neutrons detected in the neutron monitor. In order to place the beam on the central axis of the quadrupoles, the steering of the beam was adjusted such that the ratio of detected protons to neutrons was minimally sensitive to the the quadupole current (less than a 5% change for a quadrupole current change of 25%). The deuteron beam was also monitored with a beam profiler upstream from the target. These procedures ensured that the beam was very closely aligned with the optical beam axis and centered on the target. Following these quadrupole tests, a shield, graphite target and a polyethylene target were placed in the target holders to be activated for about 1.5 hours, during which time the proton telescope pulses were recorded. Three identical sets of targets were available to be used consecutively in order to allow enough time for any longer lived activated contaminants to decay between uses, although no contaminants were detected. When the deuteron beam was stopped, after sufficient time to allow the room radiation dose rate to fall to an acceptable level, the targets were hand-carried to the counting room and placed in the counting stations. The time between when irradiation stopped and when target counting commenced was typically 4-5 minutes. Each sample was then counted for approximately 2 hours, binned into 50 second intervals. The dead time for each time bin was recorded and used to correct the growth curve. The background proton count rate was measured at each energy setting by removing the polyethylene target and counting for approximately 30 minutes. A separate graphite disk target and shield was used exclusively for this purpose. IV. A. ANALYSIS Overview The 11 C decays in the activated polyethylene and graphite targets were counted using pairs of NaI detectors “sandwiching” each target, capable of counting the 511 keV gamma rays from positron annihilation in both singles and coincidence modes simultaneously. This allowed the 11 B growth curves from 11 C → 11 B + e+ + ν to be measured for both singles and coincidence events, and fit with the exponential growth function R(tc ) = R0 (1 − e−λtc ) + Atc + B (1) where R(tc ) is the sum of all the positron annihilation events counted up to time tc , R0 is the total number of detectable 11 C decays, λ = 20.364 ± 0.014 min [12] is the decay constant for 11 C and Atc + B is the integral of the constant rate of background events. The number of counts N0 that would be obtained if counting began immediately at the end of activation is N0 = R0 eλttrans (2) where ttrans is the time between the end of activation and the start of counting, in other words, the time required to transfer the samples to the counting station. The total number of 11 C nuclei formed in the target is N0 (3)  where  is either the absolute full-peak coincidence or singles efficiency, depending on how the growth curve was generated. Cross sections σ for 12 C(n,2n) were extracted using the above quantities as well as the background-subtracted rate of elastically scattered protons detected, Np , and the activation time, t, since   N0 1 λ Np 1 σ= (4)  TC 1 − e−λt Nn Np N11 C = where TC is the target thickness in terms of carbon nuclei (carbon nuclei/cm2 ). The quantity (Np /Nn ) is the ratio of elastically scattered protons detected, Np , to the number of neutrons striking the polyethylene or graphite target, Nn . This ratio was calculated numerically for the experiment geometry for each target using the known 3 H(d,n)4 He [13] and 1 H(n,p)n elastic scattering [14, 15] cross sections. B. Growth Curves To determine R0 , Eq. (1) was fit to the growth curves for the polyethylene and graphite targets using the c++ 6 of protons Np using Residual 100 Nn =  0 Integrated Counts (103) 3 30 25 20 15 10 5 (a) 20 40 60 Time (min) 80 100 FIG. 5. (a) Fit of Eq. (1) to the coincidence growth curve and (b) residuals for the graphite target activated by 26.3 MeV neutrons. The uncertainties shown were calculated using the integrated number√of counts (a) and the incremental number for each time bin Ni − Ni−1 (b). ROOT [16] TMinuit class implementation of the Minuit package [17]. Fits were made using singles events from each NaI detector individually and also for coincidence events, resulting in six semi-independent measurements of the cross section. For the polyethylene target, which is much thinner than the graphite, at the highest incident neutron energy setting about 7000 11 C decays were counted over the 2 hour period. Fig. 5 shows a typical fit of Eq. (1) to a coincidence growth curve. These growth curves were created by integrating the number of events in the 511 keV peak up to time tc , and plotting the integral as a function of tc . The exponential nature of the growth curve was clear for coincidence events, but because of the large number of background events relative to the number of 11 C decays, the singles growth curves for the thin polyethylene targets were nearly a straight lines. Nevertheless, the value of R0 could still be extracted from these fits and used to determine the cross section using Eq. (4) , albeit with a larger uncertainty. C.  Np (5) (b) −100 ×10 0 0 1 Np Nn Determination of (Np /Nn ) In order to figure out the cross section for the 12 C(n, 2n)11 C reaction using Eq. (4), the incident neutron flux Nn striking each target was determined from the number where the quantity in parenthesis, (Np /Nn ), the ratio of the number of protons detected to neutrons striking the target was calculated purely from the experiment geometry. To calculate the ratio (Np /Nn ) for each target, several simplifying assumptions were made to which corrections were later applied. Assume that the tritium target is a point source of monoenergetic neutrons, isotropic in the lab frame, with flux N (neutrons/sec/sr). In that case, the number of neutrons/sec (Nn ) striking the polyethylene (Nn = NCH2 ) and graphite (Nn = NG ) targets would be given by NCH2 = N ΩCH2 and NG = N ΩG where ΩCH2 and ΩG are the solid angles of the plastic and graphite targets, respectively, if the effect of the finite thickness of the targets on solid angle is neglected. The number of protons/sec (Np ) detected by the proton telescope can be obtained if the polyethylene target is then treated as a point source for the purpose of scattering protons into the proton telescope. Assuming that the cross section for 1 H(n,p) elastic scattering, σnp (ψnp , En ), which depends on the scattering angle, ψnp , and the incident neutron energy, En , is roughly constant over the angles subtended by the targets, and is equal to the cross section at 0◦ at the nominal neutron energy, yields Np = σnp (0◦ )TH Nn Ωp (6) where TH is the thickness (hydrogen nuclei/area) of the polyethylene target, and Ωp is the solid angle of the proton telescope. In this simple approximation, therefore, the calculated ratio of the rates for protons detected by the proton telescope to neutrons hitting the polyethylene target is   Np Np = = σnp (0◦ )TH Ωp (7) Nn CH2 NCH2 and for the graphite target   Np Np ΩCH2 Ωp = = σnp (0◦ )TH . Nn G NG ΩG (8) Clearly, the approximation that the tritium and polyethylene targets can be treated as point sources is incorrect, and a more correct solution must include the fact that the neutrons leaving the tritium target can have a range of angles and still reach the polyethylene and graphite targets, and that the energies and cross sections for these neutrons depends on the neutron angle. Moreover, the protons coming from the polyethylene, which is actually an extended source, can also have a range of angles and still strike the proton telescope, and the cross sections and energies of the protons reaching the telescope depends on the proton angle. 7 based on the rate of convergence to give around 1% uncertainty in the proton-to-neutron ratio. The scattering angles for the DT fusion and 1 H(n,p) elastic scattering reactions for each neutron and proton path were determined for each step. No neutron scattered at an angle of greater than around 17◦ was able to hit the graphite target. No proton scattered at an angle greater than around 25◦ could hit the detector. Since these extreme angles were very unlikely, most paths had cross sections fairly close to the 0◦ approximation. The cross section measurement was insensitive to the Ti:T ratio and the overall tritium activity of the tritium target, since the neutron flux was measured directly using the proton telescope. However, the neutrons striking the graphite and polyethylene targets are slightly reduced in energy and have a broadened energy distribution as a result of the deuterons losing energy prior to interact0 0 0 0 ing with the tritium, and the resulting neutrons leaving cos φdt ×Fd Tt rt drt dθt rdrdθ. (9) at angles greater than 0◦ . The thickness of the tritium 2 Rn target was also divided into 150 steps, and for each step where Rt is the radius of the beam spot on the tritium in thickness and angle the energy of the neutrons striktarget (0.635 cm), R is the radius of the polyethylene taring the targets was calculated. The calculated neutron get, the incident deuteron energy is Ed , the deuteron flux spectra were used to correct the nominal neutron ener(deuterons/area/time) is Fd , the thickness of the tritium gies. To do this, for neutron energies above about 21.5 target (3 H nuclei per unit area) is Tt , and the surface MeV, where the 12 C(n, 2n)11 C cross sections are large area of the tritium target is At . The cross section for enough to allow, a quadratic polynomial was fit to the DT fusion at the neutron angle φdt for incident deuteron measured 12 C(n, 2n)11 C cross sections as a function of energy Ed is σdt (φdt , Ed ) where φdt = cos−1 (Rn · ẑ/Rn ). uncorrected nominal neutron energy. This was used with The number of neutrons impacting the graphite target the calculated neutron energy spectrum to predict the (NG ) was calculated using the same formula by integratexpected 11 C distribution in each target. Then the toing over the surface area of the graphite target rather tal 11 C in the target and the preliminary cross section than the polyethylene target, remembering to include the fit were used to determine the corrected neutron energy central hole. – that is, if all the neutrons had this energy, they would give the same number of 11 C nuclei as the actual neutron The rate of protons striking the proton telescope due 1 distribution. This process resulted in a maximum downto H(n,p) elastic scattering of DT neutrons from protons ward shift in neutron energy of less than 1.3% (0.28 MeV) in the plastic target is given by which occurred for 5.57 MeV deuterons. The FWHM of Z 2π Z Rdet Z 2π Z R Z 2π Z Rt Np = σnp (ψnp , En (φdt , Ed )) the energy neutron energy distribution striking the targets was typically about 0.3 MeV. For deuteron energies 0 0 0 0 0 0 below 21.5 MeV, where the 12 C(n, 2n)11 C cross section TH cos φdt ×σdt (φdt , Ed )Fd Tt rt drt dθt rdrdθ is essentially zero, the average was used to estimate the cos φdt Rn2 corrected neutron energy. cos φnp The proton energy variation with angle for protons en× r dr dθ . (10) det det det Rp2 tering the proton telescope is wider, but still only 5 MeV for 26 MeV protons, which allowed the protons to be where Rdet is the radius of the proton detector, easily identified in the E-∆E telescope. En (φdt , Ed ) is the DT neutron energy, which depends Fig. 7 shows how the corrected ratio (Np /Nn ), comon the deuteron energy and DT neutron angle φdt , and puted using Eq. (10) and Eq. (9), compares to the ap−1 ψnp is the np scattering angle, given by ψnp = cos (Rn · proximate value determined using Eq. (7) and (8). The Rp /Rn Rp ). net effect of all these corrections was always less than The hole through the center of the graphite target was about 7%. slightly too small for all of the protons to pass through unobstructed, thereby causing a collimating effect. To correct this, if in the integral any proton path intersected D. Absolute Full-peak Efficiencies for Singles and the graphite disk it was excluded from the integral. This Coincidence changed Np by less than 0.5%. A c++ program was written to evaluate these integrals Because the activated targets were sandwiched benumerically using the rectangle method. Each integral tween the NaI detectors in order to maximize the count was divided into 150 steps, the number of steps chosen A number of corrections were applied to this simple calculation of the (Np /Nn ) proton to neutron ratio. The first correction accounts for the fact that the targets were not point sources but actually extended targets. The 1 H(n,p) elastic scattering and DT fusion cross sections both depend on the scattering angle, as do the energies of the scattered neutrons and protons. To account for these effects, the surface of each target and the silicon detector were divided into infinitesimally small area elements, each of which was then treated as a point source. The total number of protons or neutrons hitting a target or detector was determined by integrating over the surface area of each target, as depicted in Fig. 6. The rate of neutrons hitting the polyethylene target is Z 2π Z R Z 2π Z Rt σdt (φdt , Ed ) NCH2 = 8 CH2 Tritium Fd (rt, θt) (rdet, θdet) dt z Detector Rn Tt np (r, θ) Rp np TH FIG. 6. Schematic diagram showing quantities used to calculate the (Np /Nn ) proton to neutron ratio for extended targets. A neutron can travel from an infinitesimal area element at polar coordinates (rt , θt ) on the tritium target to an area element at polar coordinates (r, θ) on the polyethylene target along vector Rn . A proton can then travel from there to the area element at polar coordinates (rdet , θdet ) on the detector along vector Rp . The total number of neutrons or protons were determined by integrating over the surfaces of the involved targets or detector. The z coordinate axis is along the center of the beam line. 1.10 Ratio 1.05 1.00 0.95 0.90 2.8 4.8 6.8 En (MeV) 8.8 FIG. 7. The ratio of (Np /Nn ) determined by integration using Eq. (10) and Eq. (9) to the value determined using the simple approximate approach of Eq. (7) and Eq. (8) for the graphite(red squares) and the polyethylene targets (blue diamonds). rate, the efficiency was very sensitive to geometry. A Monte Carlo simulation was created using the Geant4 toolkit [18, 19] to model both the graphite and polyethylene target geometries, including other decay modes, surrounding materials, and Compton scattering. In order to validate this code, it was used to predict efficiencies for other geometries which were then tested experimentally. These experiments will be described in more detail in a later paper. In the first set of tests, an associated particle technique was used to allow the absolute singles and coincidence full-peak efficiencies to be determined using an uncalibrated 22 Na positron source. In this technique the positrons were stopped in a plastic scintillator, signaling that a pair of 511 keV gamma rays were released. The fraction of plastic scintillator events for which the NaI detector also detected a 511 keV gamma ray in coincidence is the absolute efficiency. A third detector was used to correct for summing with the 1.274 MeV gamma rays from the 22 Na. The geometry of the plastic scintillator and 22 Na source were simulated, and compared with predicted singles and coincidence absolute full-peak efficiencies as a function of source-to-detector distance and radial source position on the face of the detector. The code predictions agreed with the measurements to within approximately 4.7% RMS percent difference for coincidence, and 8.6% for singles. The second set of tests used an approximately 3.7 kBq NIST calibrated 68 Ge source, with activity measured to 1.7%. For the initial test, the source was sandwiched between two copper disks to stop the positrons, nearly simulating a point source. Again the geometry was simulated and predicted singles and coincidence absolute fullpeak efficiencies were compared with measurements as a function of source-to-detector distance and radial source position on the face of the detector, agreeing to about 5.3% RMS percent difference for coincidence, and 6.6% for singles. Finally, the 68 Ge source was placed between graphite disks of the same diameter and approximate thickness as in the experiment, and the full-peak efficiencies were measured as a function of radial source position. In this experiment, which is the closest to the actual measurement geometry, the predicted efficiencies agreed with the measurement to 6.5% RMS percent difference for coincidence, and 1.4% for singles. The GEANT simulation code was used to study the effect of misaligning at axes of the targets and NaI detectors. In the worst case, which was for coincidence measurements using the graphite target, an offset of 1 mm of the target resulted a 3.1% change in the full-peak 9 TABLE II. The absolute full-peak efficiencies used in the cross section calculation. Target Graphite Polyethylene Configuration Coincidence Detector 1 Detector 2 Coincidence Detector 1 Detector 2 Efficiency 0.0494 ± 0.0027 0.0981 ± 0.0054 0.1049 ± 0.0058 0.1568 ± 0.0078 0.1655 ± 0.0091 0.1656 ± 0.0091 efficiency. Based on these results, a systematic uncertainty of 5.5% was assigned for the predicted absolute full-peak efficiencies for the targets used in this experiment, which are listed in Table II. Given the large size of the graphite target used in this experiment, the Monte Carlo simulation code MCNP5 [20] was used to reproduce the distribution of 11 C nuclei in the graphite disk. In this simulation, monoenergetic neutrons were emitted uniformly and isotropically from a circular region on the flat tritium target, with a radius equal to that of the last upstream collimator on the deuteron beam. The interactions of these neutrons with the graphite disk were simulated using the standard 6000.60c cross section library, and resulting number of 11 C nuclei were mesh tallied as a function of position within the graphite. The simulation showed, relatively independently of the neutron energy, that the number of 11 C was reduced to about 75% at the downstream face relative to the upstream face of the graphite, and smoothly fell by approximately 5% from the center to the edge. Simulating this 11 C distribution in the Geant4 code slightly increased the singles absolute full-peak efficiency for the detector with more 11 C near it and reduced the other side; for coincidences the efficiency was increased by nearly 6%. E. Measurement Uncertainty The uncertainty in the cross section from Eq. (4) was calculated using the normal propagation of uncertainty rules to get ( 2  2  2 δN0 δ δTC 2 2 (δσ) = σ + + N0  TC )  2  2 δNn 1 te−λt 2 + + − (δλ) .(11) Nn λ 1 − e−λt where the uncertainty in the activation time t is so small it has been neglected. The range of uncertainty values for each term in Eq. (11) is shown in Table III, and the results are included in the uncertainties given in Table IV and Figs. 1 and 8. The estimates for statistical uncertainty in the number of 11 C decays result from the error matrix calculated by TMinuit in fitting Eq. (3). The range of values in Table III result from the large change in the number of 11 C produced in each target, since the 12 C(n, 2n)11 C cross section rises rapidly near threshold. The uncertainty in the number of neutrons, determined from (Nn /Np ) Np , depends on the statistical uncertainty in Np the number of protons detected (about 1.1%), the uncertainty in the 1 H(n,p)n elastic scattering cross section σnp [14, 21] (about 0.7%), the uncertainty in TH , the polyethylene 1 H number density (about 3.5%), and the solid angle uncertainties for the polyethylene and graphite targets, and the proton telescope (about 2.8%, 1.4%, and 2.9% respectively). The effect of misaligning the axes of the polyethelene and graphite targets was simulated and found to result in approximately an additional 4.1% uncertainty in the number of neutrons striking the graphite target. Since the neutrons striking the polyethylene target determines the number of protons, this systematic effect does not affect the polyethylene uncertainty. The uncertainties in the 12 C and 1 H areal number densities (TC and TH respectively) for each of the targets was estimated based on careful measurements of the target dimensions and mass. The uncertainty in the corrected incident neutron energy was assumed due to the uncertainty in the thickness of the tritium target, which was about ±0.7%. The neutron energy uncertainty was propagated into the 12 C(n, 2n)11 C cross section uncertainty using the slope of a polynomial fit to the nominal 12 C(n, 2n)11 C cross sections as a function of energy. The resulting cross section uncertainties, which ranged from 0.31 mb to 0.85 mb, were added in quadrature to the other uncertainties described above. V. DISCUSSION OF EXPERIMENTAL RESULTS The total 12 C(n,2n)11 C cross sections obtained from the graphite and polyethylene targets, for coincidence and singles counting, are displayed in Table IV. The agreement between cross sections determined using different targets, geometries, efficiencies and detectors is quite good; the overall RMS percent difference from the mean for energies above 22 MeV, where there are enough statistics to be meaningful, is 6.2%. The best individual measurement is expected to be the coincidence measurement using the polyethylene target, since the background rate is reduced for the coincidence measurement, allowing a more robust fit to the growth curve, and since the same target is used for 1 H(n,p) elastic scattering, eliminating systematic uncertainties in determining the neutron flux. Fig. 8 plots the cross sections measured in this experiment for different combinations of targets and detectors. Fig. 8a shows the overall agreement between all of the measurements made at each neutron energy. The agreement is good, but with the graphite coincidence measurement being systematically high. Figs. 8b, c and d compare just the polyethylene and graphite cross 10 TABLE III. Contribution to the cross section uncertainty from each term in Eq. (11) corresponding to the factors in Eq. (4). For the statistical uncertainties in the number of 11 C and incident neutrons, the ranges given are for energies above about 21.5 MeV, where the cross section is large enough for this to be meaningful. Percent Uncertainty Source Uncertainty in N0 Graphite target 11 C decays counted 11 C decays counted 11 C decays counted Polyethylene target 11 C decays counted 11 C decays counted 11 C decays counted in coincidence in NaI1 detector in NaI2 detector 0.3-0.9% 0.2-1.0% 0.2-1.0% in coincidence in NaI1 detector in NaI2 detector 0.7-2.3% 1.0-9.5% 1.0-5.5% Uncertainty in NaI detector efficiency  5.5% Uncertainty in 12 C areal number density TC Graphite target Polyethylene target 1.9% 3.8% Uncertainty in incident neutrons Nn Graphite target Polyethylene target 6.9% 4.6% Uncertainty in λ/1 − e−λt 0.6%  sections for coincidence and singles measurements using each detector. Comparing measurements with different targets made using the same detector(s) shows agreement within experimental uncertainty, which is a fairly stringent test since the geometry and target material is not the same, supporting the calculated detector efficiency and geometry correction. The measurement at 24.7 MeV was repeated, the first measurement made near the middle of the experiment and the second at the end. In this case, the coincidence measurements at the middle and end of the experiment agree when comparing graphite to graphite and polyethylene to polyethylene, but the graphite result is higher than the polyethylene for both measurements, slightly outside of the error bars. It is clear from Fig. 1 that the cross sections from the present experiment fall along high side of the upper curve previously set by the measurements of Anders et al. [6] and Welch et al. [7] and calculations of Dimbylow [5]. The predictions of Dimbylow [5] are within our error bars, as are, for the most part, the measurements from Anders et al [6] and Welch et al. [7]. VI. CONCLUSION The cross sections for 12 C(n, 2n)11 C have been measured using an activation technique from threshold to 26.3 MeV with an uncertainty of approximately 9-12% for the higher energies. Previous measurements disagree, tending to fall into upper and lower bands. The results of the present experiment agree with the upper band. Accurate cross sections may allow the 12 C(n, 2n) reaction to be used as neutron diagnostic for ICF. During an ICF implosion, primary and tertiary DT fusion reaction neutrons are produced. Since the ion plasma temperatures in these thermonuclear implosions are typically in the keV range, the primary DT neutron energy is Q value driven. The energy distribution of primary neutrons is typically peaked around 14.1 MeV and has a small thermodynamic width which is broadened further via straggling by the compressed fuel. These neutrons are copious and exceed the production of tertiary neutrons by six to seven orders of magnitude. Conversely, neutrons which are produced by DT fusion reactions caused by upscattered MeV DT fuel generate tertiary neutrons with energies in the 10 to 32 MeV range. Since the 12 C(n, 2n) reaction is insensitive to energies below 20 MeV, the primary 14.1 MeV DT and down scattered primary neutrons cannot react with the carbon. Only tertiary neutrons in 20 to 32 MeV range react making this method useful as a possible ICF tertiary neutron diagnostic. To use this method, ultra-pure graphite disks placed within the ICF reaction chamber become activated by tertiary neutrons via the 12 C(n, 2n)11 C reaction. The 11 C in the disk subsequently decays via positron emission, and the 511 keV annihilation gamma rays are then counted in coincidence using a detector system far from the target chamber. The gamma counts can then be used to obtain the tertiary neutron yield, limited by the uncertainty in the 12 C(n, 2n)11 C cross section. ACKNOWLEDGMENTS We would like to thank Andrew Evans, Keith Mann, Tyler Reynolds, Ian Love, August Gula, Laurel Vincett, Lee Gabler, Michael Krieger, Mollie Bienstock, Collin Stillman, Drew Ellison, and Holly Desmitt for assistance performing the experiment, and Shamim Akhtar, Don Carter, Sushil Dhakal, Devon Jacobs, John O’Donnell, and Andrea Richard for assistance at Ohio University. This research is funded in part by the University of Rochester Laboratory for Laser Energetics through a grant from the Department of Energy and by the U.S. Department of Energy, under Grant Nos. DE-FG0288ER40387, DE-NA0001837, and DE-NA0002905. Certain commercial equipment, instruments, or materials are identified in this paper to foster understanding. Such identification does not imply recommendation or endorsement by the National Institute of Standards and Technology, nor does it imply that the materials or equipment identified are necessarily the best available for the purpose. 11 TABLE IV. Total 12 C(n, 2n)11 C cross sections obtained from the graphite and polyethylene targets, for coincidence and singles counting. Also shown is the weighted mean for each energy. The uncertainties quoted are discussed in the text. Deuteron Energy (MeV) 3.57 4.07 4.57 5.07 5.57 6.07 6.57 7.07 7.57 7.57 8.07 8.57 9.07 Energy (MeV) 20.06 20.67 21.27 21.79 22.35 22.92 23.51 24.11 24.69 24.69 25.25 25.77 26.25 Graphite Coincidence Detector 1 (mb) (mb) 0.00 ± 0.00 -0.05 ± 0.01 0.08 ± 0.01 0.07 ± 0.01 0.78 ± 0.32 0.75 ± 0.31 2.69 ± 0.43 4.03 ± 0.51 4.37 ± 0.57 4.23 ± 0.56 6.76 ± 0.77 6.56 ± 0.76 8.19 ± 0.92 7.72 ± 0.88 8.89 ± 1.01 8.53 ± 0.98 12.34 ± 1.31 11.62 ± 1.26 12.19 ± 1.30 9.66 ± 1.11 13.45 ± 1.44 12.62 ± 1.37 15.91 ± 1.67 13.86 ± 1.51 18.16 ± 1.89 16.80 ± 1.78 Detector 2 (mb) 0.02 ± 0.01 0.10 ± 0.01 0.70 ± 0.31 3.78 ± 0.49 3.96 ± 0.54 6.12 ± 0.73 7.25 ± 0.85 7.83 ± 0.93 11.17 ± 1.22 9.04 ± 1.06 11.81 ± 1.31 13.05 ± 1.44 16.07 ± 1.72 [1] D. Welch, H. Kislev, and G. Miley, Rev Sci Instrum 59, 610 (1988). [2] V. Y. Glebov, C. Stoeckl, T. Sangster, D. Meyerhofer, P. Radha, S. Padalino, L. Baumgart, R. Colburn, and J. Fuschino, Rev Sci Instrum 74, 1717 (2003). [3] C. Galbiati, A. Pocar, D. Franco, A. Ianni, L. Cadonati, and S. Schönert, Phys. Rev. C 71, 055805 (2005). [4] G. Audi, F. Kondev, M. Wang, B. Pfeiffer, X. Sun, J. Blachot, and M. MacCormick, Chin. Phys. C 36, 1157 (2012). [5] P. Dimbylow, Phys. Med. Biol. 25, 637 (1980). [6] B. Anders, P. Herges, and W. Scobel, Z. Phys. A 301, 353 (1981). [7] P. Welch, J. Johnson, G. Randers-Pehrson, and J. Rapaport, Bull. Am. Phys. Soc 26, 708 (1981). [8] J. Brolley Jr, J. Fowler, and L. Schlacks, Phys. Rev. 88, 618 (1952). [9] O. D. Brill, N. A. Vlasov, S. P. Kalinin, and L. S. Sokolov, Dok. Akad. Nauk SSSR 136, 55 (1961), [Sov. Phys. Dokl. 6, 24-26 (1961)]. [10] T. S. Soewarsono, Y. Uwamino, and T. Nakamura, in Proceedings of the 1991 Symposium on Nuclear Data, JAERI-M 92-027, edited by M. Baba and T. Nakagawa (Tokyo, Tokai, Ibaraki-ken. Japan, 1992) pp. 354–363. [11] Y. Uno, Y. Uwamino, T. S. Soewarsono, and T. Nakamura, Nucl Sci Eng 122, 247 (1996). Energy (MeV) 20.10 20.71 21.31 21.83 22.39 22.97 23.56 24.15 24.74 24.74 25.29 25.82 26.29 Polyethylene Coincidence Detector 1 (mb) (mb) 0.00 ± 0.01 -0.03 ± 0.13 0.08 ± 0.01 0.50 ± 0.11 0.88 ± 0.32 0.79 ± 0.33 2.53 ± 0.41 4.04 ± 0.49 4.02 ± 0.52 4.14 ± 0.53 6.49 ± 0.70 6.00 ± 0.69 7.58 ± 0.80 7.43 ± 0.80 8.50 ± 0.90 8.18 ± 0.88 11.09 ± 1.10 10.70 ± 1.08 10.77 ± 1.08 8.58 ± 0.95 12.04 ± 1.20 11.44 ± 1.16 13.91 ± 1.36 13.36 ± 1.32 16.55 ± 1.56 16.43 ± 1.56 Detector 2 (mb) -0.20 ± 0.01 0.12 ± 0.01 1.49 ± 0.32 3.72 ± 0.41 3.83 ± 0.52 6.44 ± 0.70 7.48 ± 0.80 8.49 ± 0.90 10.77 ± 1.10 9.59 ± 1.08 12.75 ± 1.20 12.57 ± 1.36 16.94 ± 1.56 [12] J. H. Kelley, E. Kwan, J. Purcell, C. Sheu, and H. Weller, Nucl. Phys. A 880, 88 (2012). [13] M. Drosg, DROSG-2000: Neutron source reactions., Tech. Rep. IAEA-NDS-87 Rev. 5 (International Atomic Energy Agency, Nuclear Data Section, Vienna (Austria), 2000). [14] V. Stoks, R. Klomp, M. Rentmeester, and J. De Swart, Phys. Rev. C 48, 792 (1993). [15] V. Stoks, R. Klomp, C. Terheggen, and J. De Swart, Phys. Rev. C 49, 2950 (1994). [16] R. Brun and F. Rademakers, Nucl. Instrum. Methods Phys. Res. A 389, 81 (1997). [17] F. James and M. Winkler, MINUIT–Users Guide, Program Library D506, CERN, Geneva (1998). [18] S. Agostinelli, J. Allison, K. a. Amako, J. Apostolakis, H. Araujo, P. Arce, M. Asai, D. Axen, S. Banerjee, G. Barrand, et al., Nucl. Instrum. Methods Phys. Res. A 506, 250 (2003). [19] J. Allison, K. Amako, J. e. a. Apostolakis, H. Araujo, P. A. Dubois, M. Asai, G. Barrand, R. Capra, S. Chauvie, R. Chytracek, et al., Nuclear Science, IEEE Transactions on 53, 270 (2006). [20] X. Team, Los Alamos National Lab Report: LA-UR-031987 (2003). [21] V. Stoks, R. Timmermans, and J. De Swart, Phys. Rev. C 47, 512 (1993). Cross Section (mbarn) 12 20 20 (a) (b) 15 15 10 10 5 5 0 20 0 20 21 22 23 24 25 26 20 20 (c) 15 10 10 5 5 0 0 21 22 23 24 25 26 22 23 24 25 26 (d) 15 20 21 22 23 24 25 26 20 21 Neutron Energy (MeV) FIG. 8. Comparison of the cross sections measured in this experiment using the graphite (circles) and polyethylene (diamonds) targets for (b) both NaI detectors in coincidence (red), and (c) NaI detector 1 (blue) and (d) NaI detector 2 (green) in singles mode. Figure (a) shows cross sections determined using both coincidence and singles information for both targets on the same plot. For each cross section, the larger of the associated error bars indicates the increase in overall uncertainty when the uncertainty in incident neutron energy is included.