Cerebral MES During PVI. Introduction: Isolation of the pulmonary veins (PVI) using high ablation... more Cerebral MES During PVI. Introduction: Isolation of the pulmonary veins (PVI) using high ablation energy is an effective treatment for atrial fibrillation (AF) with a success rate of 50-95%; however, postoperative neurological complications still occur in 0.5-10%. In this study the incidence of cerebral microembolic signals (MES) as a risk factor for neurological complications is examined during 3 percutaneous endocardial ablation procedure strategies: segmental PVI using a conventional radiofrequency (RF) ablation catheter, segmental PVI using an irrigated RF tip catheter, and circumferential PVI with a cryoballoon catheter (CB). Methods and Results: Thirty patients underwent percutaneous endocardial PVI. Ostial isolation was performed in 10 patients with a conventional 4-mm RF catheter (CRF) and in 10 patients with a 4-mm irrigated RF catheter (IRF). A circumferential PVI was performed in 10 patients with a CB. Transcranial Doppler (TCD) monitoring was used to detect MES in the middle cerebral arteries. The total number of cerebral MES differs significantly among the 3 PVI groups; 3,908 cerebral MES were measured with use of the CRF catheter, 1,404 cerebral MES with use of the IRF catheter, and 935 cerebral MES with use of the CB catheter. Conclusion: This study demonstrates a significant difference in cerebral MES during PVI with 3 different ablation procedures. The use of an irrigated RF and a cryoballoon produces significantly fewer cerebral MES than the use of conventional RF for a PVI procedure, suggesting a higher risk for neurologic complications using conventional RF energy during a percutaneous PVI procedure.
Adenosine is routinely used during ventricular pacing to exclude the persistence of retrograde ac... more Adenosine is routinely used during ventricular pacing to exclude the persistence of retrograde accessory pathways conduction after radiofrequency (RF) ablation procedures by blocking conduction over the atrioventricular node. This is the first report of an adenosine-dependent concealed accessory pathway demonstrating transient conduction only after adenosine administration. Our findings may have potential clinical implications in reducing recurrence after accessory pathway ablation. Furthermore, it may add relevant information regarding the ability of adenosine to elicit dormant conduction after RF ablation, a phenomenon that has acquired considerable interest in the era of pulmonary vein isolation.
Circulation. Arrhythmia and electrophysiology, 2013
Pulmonary vein isolation has increasingly been used to cure atrial fibrillation, but concerns hav... more Pulmonary vein isolation has increasingly been used to cure atrial fibrillation, but concerns have recently been raised that subclinical brain damage may occur because of microembolization during these procedures. We compared the occurrence of bubble formation seen on intracardiac echocardiography and the microembolic signals (MESs) detected by transcranial Doppler on the use of different ablation techniques and anticoagulation strategies. This prospective study included 35 procedures in 34 consecutive patients (age, 52; SD, 12.8 years; female:male 9:25). Pulmonary vein isolation was performed with a cryoballoon and the conventional anticoagulation protocol (activated clotting time >250 s) in 10 procedures (group 1), with a multipolar duty-cycled radiofrequency pulmonary group 2), and with regime a pulmonary vein ablation catheter with an aggressive anticoagulation (activated clotting time >320 s) in 13 procedures (group 3). The mean total numbers of MESs detected during the p...
Cerebral MES During PVI. Introduction: Isolation of the pulmonary veins (PVI) using high ablation... more Cerebral MES During PVI. Introduction: Isolation of the pulmonary veins (PVI) using high ablation energy is an effective treatment for atrial fibrillation (AF) with a success rate of 50-95%; however, postoperative neurological complications still occur in 0.5-10%. In this study the incidence of cerebral microembolic signals (MES) as a risk factor for neurological complications is examined during 3 percutaneous endocardial ablation procedure strategies: segmental PVI using a conventional radiofrequency (RF) ablation catheter, segmental PVI using an irrigated RF tip catheter, and circumferential PVI with a cryoballoon catheter (CB). Methods and Results: Thirty patients underwent percutaneous endocardial PVI. Ostial isolation was performed in 10 patients with a conventional 4-mm RF catheter (CRF) and in 10 patients with a 4-mm irrigated RF catheter (IRF). A circumferential PVI was performed in 10 patients with a CB. Transcranial Doppler (TCD) monitoring was used to detect MES in the middle cerebral arteries. The total number of cerebral MES differs significantly among the 3 PVI groups; 3,908 cerebral MES were measured with use of the CRF catheter, 1,404 cerebral MES with use of the IRF catheter, and 935 cerebral MES with use of the CB catheter. Conclusion: This study demonstrates a significant difference in cerebral MES during PVI with 3 different ablation procedures. The use of an irrigated RF and a cryoballoon produces significantly fewer cerebral MES than the use of conventional RF for a PVI procedure, suggesting a higher risk for neurologic complications using conventional RF energy during a percutaneous PVI procedure.
Adenosine is routinely used during ventricular pacing to exclude the persistence of retrograde ac... more Adenosine is routinely used during ventricular pacing to exclude the persistence of retrograde accessory pathways conduction after radiofrequency (RF) ablation procedures by blocking conduction over the atrioventricular node. This is the first report of an adenosine-dependent concealed accessory pathway demonstrating transient conduction only after adenosine administration. Our findings may have potential clinical implications in reducing recurrence after accessory pathway ablation. Furthermore, it may add relevant information regarding the ability of adenosine to elicit dormant conduction after RF ablation, a phenomenon that has acquired considerable interest in the era of pulmonary vein isolation.
Circulation. Arrhythmia and electrophysiology, 2013
Pulmonary vein isolation has increasingly been used to cure atrial fibrillation, but concerns hav... more Pulmonary vein isolation has increasingly been used to cure atrial fibrillation, but concerns have recently been raised that subclinical brain damage may occur because of microembolization during these procedures. We compared the occurrence of bubble formation seen on intracardiac echocardiography and the microembolic signals (MESs) detected by transcranial Doppler on the use of different ablation techniques and anticoagulation strategies. This prospective study included 35 procedures in 34 consecutive patients (age, 52; SD, 12.8 years; female:male 9:25). Pulmonary vein isolation was performed with a cryoballoon and the conventional anticoagulation protocol (activated clotting time >250 s) in 10 procedures (group 1), with a multipolar duty-cycled radiofrequency pulmonary group 2), and with regime a pulmonary vein ablation catheter with an aggressive anticoagulation (activated clotting time >320 s) in 13 procedures (group 3). The mean total numbers of MESs detected during the p...
Uploads
Papers by I. Beke