Plastic laboratory materials are found to affect vital parameters of the waterflea Daphnia magna.... more Plastic laboratory materials are found to affect vital parameters of the waterflea Daphnia magna. The main responsible factor is defined as "newness" of the materials. Juvenile D. magna were raised individually in; a) new laboratory-standard 50 ml polypropylene tubes, and; b) identical tubes which had been washed and aerated for several weeks. Newness had significant effects on growth and fecundity of D. magna. New tubes caused delayed maturation, reduced reproduction and reduced growth when compared to washed and re-used tubes of the same commercial brand. The findings indicate that newness of tubes has inhibiting or toxic effects on D. magna. Often laboratory plastics are intended for single-use due to sterility demands. Newness might be an important confounding factor in research results and should not be disregarded. Disposable plastic utensils may come with a seemingly ignored cost and induce adverse effects in biological test-organisms and systems. The presented find...
The cross-reactivity of antibodies employed within immunochemistry-based analytical methods may l... more The cross-reactivity of antibodies employed within immunochemistry-based analytical methods may lead to overestimation of the results. Under certain conditions, specifically when controlling mycotoxin maximum limits serious problems can be encountered. Not only the structurally related mycotoxins, such as their masked (conjugated) forms, but also the unidentified matrix components are responsible for concentration overestimation of respective target analytes. The cross-reactivity phenomenon may also pose a risk of miss-interpretation of the proficiency tests results, when the assigned value becomes influenced by over-estimated results reported by users of immunochemical tests. In this paper, the current state of the knowledge on trueness problems associated with the rapid screening immunochemical methods have been reviewed. Special attention is focused on discussion of cross-reactivity in the ELISA tests, because this rapid test dominates the routine screening practice. However, the...
A sensitive and reproducible gas chromatographic procedure for the determination of diquat and pa... more A sensitive and reproducible gas chromatographic procedure for the determination of diquat and paraquat in potatoes and rapeseed was developed. The volatilization of analytes was carried out via their hydrogenation with sodium borohydride-nickel(II) chloride. After their isolation from the reaction mixture, the derivatives of bipiperidine were separated on a column packed with Apiezon L plus potassium hydroxide. Comparable detection limits (0.005 mg/kg) were achieved with a nitrogen-phosphorus detector and by mass fragmentography, however, the latter method was preferred for analyses of rapeseed extracts owing to its higher selectivity.
Plastic laboratory materials are found to affect vital parameters of the waterflea Daphnia magna.... more Plastic laboratory materials are found to affect vital parameters of the waterflea Daphnia magna. The main responsible factor is defined as "newness" of the materials. Juvenile D. magna were raised individually in; a) new laboratory-standard 50 ml polypropylene tubes, and; b) identical tubes which had been washed and aerated for several weeks. Newness had significant effects on growth and fecundity of D. magna. New tubes caused delayed maturation, reduced reproduction and reduced growth when compared to washed and re-used tubes of the same commercial brand. The findings indicate that newness of tubes has inhibiting or toxic effects on D. magna. Often laboratory plastics are intended for single-use due to sterility demands. Newness might be an important confounding factor in research results and should not be disregarded. Disposable plastic utensils may come with a seemingly ignored cost and induce adverse effects in biological test-organisms and systems. The presented find...
The cross-reactivity of antibodies employed within immunochemistry-based analytical methods may l... more The cross-reactivity of antibodies employed within immunochemistry-based analytical methods may lead to overestimation of the results. Under certain conditions, specifically when controlling mycotoxin maximum limits serious problems can be encountered. Not only the structurally related mycotoxins, such as their masked (conjugated) forms, but also the unidentified matrix components are responsible for concentration overestimation of respective target analytes. The cross-reactivity phenomenon may also pose a risk of miss-interpretation of the proficiency tests results, when the assigned value becomes influenced by over-estimated results reported by users of immunochemical tests. In this paper, the current state of the knowledge on trueness problems associated with the rapid screening immunochemical methods have been reviewed. Special attention is focused on discussion of cross-reactivity in the ELISA tests, because this rapid test dominates the routine screening practice. However, the...
A sensitive and reproducible gas chromatographic procedure for the determination of diquat and pa... more A sensitive and reproducible gas chromatographic procedure for the determination of diquat and paraquat in potatoes and rapeseed was developed. The volatilization of analytes was carried out via their hydrogenation with sodium borohydride-nickel(II) chloride. After their isolation from the reaction mixture, the derivatives of bipiperidine were separated on a column packed with Apiezon L plus potassium hydroxide. Comparable detection limits (0.005 mg/kg) were achieved with a nitrogen-phosphorus detector and by mass fragmentography, however, the latter method was preferred for analyses of rapeseed extracts owing to its higher selectivity.
Uploads
Papers by Petr Cuhra