An electrode boiler (jet type) is a type of boiler that uses electricity flowing through streams of water to create steam. The conductive and resistive properties of water are employed to carry electric current.

Technical principle

edit

The most common type of electrode boiler pumps water from the lower part of the vessel to an internal header that has nozzles that allow the water to flow to electrodes. Generally the working pressure is maintained at 10 bar. If more pressure is needed (more steam) the controls speed up the pump to increase flow through additional nozzles. As the needed pressure is reached the pump controls the flow of water to obtain the desired steam output (in unit mass per unit time) at the desired pressure. On larger systems the pump can be controlled by a variable frequency drive so energy is not wasted. This control system can also control de-aerator pumps and controls.

The electrodes are connected to a medium-voltage (1–35 kV) AC source. Electrode boilers can work on both single-phase and three-phase supplies. If DC voltage is used, electrolysis of water occurs, decomposing water into its elements H2 at the cathode (negative electrode) and O2 at the anode (positive electrode). The electrode boiler is 99.9% efficient with almost all the energy consumed producing steam.[1] Losses are radiant heat from the vessel only.

The conductivity of the water and the voltage applied determine how much steam is generated in each stream of water.

Advantages

edit
  • All electrical energy is converted to heat.
  • An electrode boiler has a very quick response time.
  • As it doesn't directly generate pollution, no pollution control system is needed.[2]
  • As compared to other boilers, electrode boilers experience little thermal stress.[3]
  • Electric boilers have few components making it easier to control and maintain.
  • Dropping water levels inhibits current flow and allows the boiler to self-regulate.

Drawbacks

edit
  • Due to the water serving as a conductor, the water becomes live at a significant portion of the input voltage. This creates a serious shock hazard when used, for example, to heat water for a bath or for tea making.[citation needed][4]
  • The conductivity of water increases with temperature, also with increasing salt content, both of which may be expected to reach a peak in summer, so heating effect is greatest when it's needed least.

Safety measures

edit

When evaporated into steam, deionized or distilled water leaves little or no ions in the boiler respectively. Thus, scale formation is reduced.

References

edit
  1. ^ "Electric Boilers - Alabama Power". Archived from the original on 2010-09-17. Retrieved 2010-03-01.
  2. ^ "C-B Package Boiler". Archived from the original on 2012-01-14. Retrieved 2011-10-03.
  3. ^ "emt-india.net". www.emt-india.net.
  4. ^ "TLC Electrical Supplies". www.tlc-direct.co.uk.