0 votes
4 answers
556 views

Measure capacitors in parallel and series to increase precision?

I measure a capacitor \$C_1\$ with an instrument that has a tolerance of measurement \$\pm 5\%.\$ I do the same with another cap \$C_2\$. Then I put \$C_1\$ and \$C_2\$ in parallel (values add up) and ...
Niculae George Razvan's user avatar
0 votes
0 answers
154 views

Capacitor tolerance at high frequencies

I was measuring a 10pF 0603 +-5% (Johanson 251R14S100JV4S) using a network analyzer at 319.5MHz. The cap came in their high q/low ESR ceramic kit. It measured about 10.7pF. But after measuring a few ...
Lance Beasley's user avatar
3 votes
4 answers
285 views

Do photodiodes have tolerances?

Below is the beginning schematic for a circuit I'm working on. We have a previous revision of that product (Rev A), and two sets of recent product (Rev B1 and B2). Rev B1 was made 2 weeks prior to Rev ...
Luke's user avatar
  • 525